Your browser doesn't support javascript.
loading
Sensitive liquid chromatography/tandem mass spectrometry method for the simultaneous determination of nine local anesthetic drugs.
Tonooka, Keiko; Naruki, Nobuhiko; Honma, Kou; Agei, Kohei; Okutsu, Mayumi; Hosono, Tetsuji; Kunisue, Yoko; Terada, Masaru; Tomobe, Koji; Shinozuka, Tatsuo.
Afiliação
  • Tonooka K; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan. Electronic address: k.tonooka@ym.hamayaku.ac.jp.
  • Naruki N; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Honma K; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Agei K; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Okutsu M; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Hosono T; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Kunisue Y; Foundation for Promotion of Material Science and Technology of Japan, 1-18-6 Kitami, Setagaya-ku, Tokyo 157-0067, Japan.
  • Terada M; Department of Legal Medicine, School of Medicine, Toho University, 5-21-16 Oomorinishi, Ota-ku, Tokyo 143-8540.
  • Tomobe K; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
  • Shinozuka T; Department of Pathophysiology, Yokohama University of Pharmacy, 601 Matanocho, Totsuka-ku, Yokohama, Kanagawa 245-0066, Japan.
Forensic Sci Int ; 265: 182-5, 2016 Aug.
Article em En | MEDLINE | ID: mdl-26986505
A high-performance liquid chromatography-tandem mass spectrometry (LC/MS/MS) with electrospray ionization (ESI) procedure for the simultaneous determination of nine local anesthetic drugs (procaine, mepivacaine, lidocaine, ropivacaine, oxybuprocaine, tetracaine, bupivacaine, T-caine and dibucaine) in human serum is described. The chromatographic separation was performed on a Mightysil-RP-18 GP II column (2.0mm×150mm, particle size 5µm). The mobile phase consisted of 10mM acetic ammonium buffer (pH 5.4) and acetonitrile and was delivered at a flow rate of 0.20mL/min. The triple quadrupole mass spectrometer was operated in positive ion mode, and multiple reaction monitoring was used for drug quantification. Solid-phase extraction of the nine local anesthetic drugs added to the human serum was performed with an Oasis(®) HLB extraction cartridges column. The method was linear for the investigated drugs over the concentration range of 10-100ng/mL. The recoveries of these drugs were in the range of 81.4-144%. The standard deviation (SD) values for all analytes were <0.10 for both intraday and interday accuracy and precision. The selectivity, accuracy and precision of this method are satisfactory for clinical and forensic applications. The sensitive and selective method offers the opportunity for the simultaneous screening and quantification, for clinical and forensic purposes, of almost all local anesthetics available in Japan.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos Relacionados ao Uso de Substâncias / Anestésicos Locais Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transtornos Relacionados ao Uso de Substâncias / Anestésicos Locais Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article