Your browser doesn't support javascript.
loading
HPLC Determination of Enantiomeric Purity of Letermovir Based on CHIRALPAK AD.
Zhang, Tao; Liao, Mengya; Tian, Ye; Wang, Fangying; Ye, TingHong; Zhang, Yiwen; Zhang, Xiaoling; Chen, Yuanwei.
Afiliação
  • Zhang T; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
  • Liao M; Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu 610072, China.
  • Tian Y; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
  • Wang F; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
  • Ye T; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
  • Zhang Y; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
  • Zhang X; College of Chemistry and Life Science, Chengdu Normal University, Chengdu 611130, China.
  • Chen Y; State Key Laboratory of Biotherapy and Cancer Center, West China Hospital, Sichuan University, and Collaborative Innovation Center for Biotherapy, Chengdu 610041, China.
J Chromatogr Sci ; 54(9): 1495-1500, 2016 Oct 17.
Article em En | MEDLINE | ID: mdl-27048643
ABSTRACT
A precise and sensitive LC method was developed and further validated for the determination of enantiomeric purity of {(4S)-8-Fluoro-2-[4-(3-methoxyphenyl)-1-piperazinyl]-3-[2-methoxy-5-(trifluoromethyl)phenyl]-3,4-dihydro-4-quinazolinyl} acetic acid (Letermovir). Baseline separation with a resolution >2.8 was accomplished within 10 min using a CHIRALPAK AD (250 mm × 4.6 mm; particle size 5 µm) column, with n-hexane/2-propanol (8020 v/v) as mobile phase at a flow rate of 1 mL min-1. The eluted analytes were monitored by UV detection at 260 nm. The effects of mobile phase composition and temperature on enantiomeric selectivity as well as resolution of enantiomers were thoroughly investigated. The calibration curves were plotted within the concentration range between 0.003 and 1 mg mL-1 (n = 14), and the recoveries between 98.24 and 101.43% were obtained, with relative standard deviation <1.29%. The limit of detection (LOD) and limit of quantitation (LOQ) for Letermovir were 0.96 and 3.15 µg mL-1; those for its enantiomer were 1.01 and 3.39 µg mL-1, respectively. The developed method was demonstrated to be accurate, robust and sensitive for the determination of enantiomeric purity of Letermovir, especially for the analysis of bulk samples.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article