Your browser doesn't support javascript.
loading
Suspected Metallic Embolism following Endovascular Treatment of Intracranial Aneurysms.
Yasuda, R; Maeda, M; Umino, M; Nakatsuka, Y; Umeda, Y; Toma, N; Sakaida, H; Suzuki, H.
Afiliação
  • Yasuda R; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki) yasudar1@gmail.com.
  • Maeda M; Radiology (M.U., M.M.), Mie University Graduate School of Medicine, Tsu, Mie, Japan.
  • Umino M; Radiology (M.U., M.M.), Mie University Graduate School of Medicine, Tsu, Mie, Japan.
  • Nakatsuka Y; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki).
  • Umeda Y; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki).
  • Toma N; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki).
  • Sakaida H; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki).
  • Suzuki H; From the Departments of Neurosurgery (R.Y., Y.N., Y.U., N.T., H.Sakaida, H.Suzuki).
AJNR Am J Neuroradiol ; 37(9): 1696-9, 2016 Sep.
Article em En | MEDLINE | ID: mdl-27102315
ABSTRACT
We describe a case series of suspected metallic embolism after coil embolization for intracranial aneurysms. Between January 2012 and December 2014, 110 intracranial aneurysms had been treated by coil embolization in our institution. In 6 cases, the postprocedural MR imaging revealed abnormal spotty lesions not detected on the preprocedural MR imaging. The lesions were also undetectable on the postprocedural CT scan. They were demonstrated as low-intensity spots on T1WI, T2WI, DWI, and T2*-weighted imaging. On DWI, they were accompanied by bright "halo," and on T2*-weighted imaging, they showed a "blooming" effect. In 3 of the 6 cases, follow-up MR imaging was available and all the lesions remained and demonstrated no signal changes. Although histologic examination had not been performed, these neuroradiologic findings strongly supported the lesions being from metallic fragments. No specific responsible device was detected after reviewing all the devices used for the neuroendovascular treatment in the 6 cases.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolia Intracraniana / Embolização Terapêutica Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aneurisma Intracraniano / Embolia Intracraniana / Embolização Terapêutica Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article