Visible blind ultraviolet photodetector based on CH3NH3PbCl3 thin film.
Opt Express ; 24(8): 8411-9, 2016 Apr 18.
Article em En | MEDLINE | ID: mdl-27137279
ABSTRACT
We report a prototypical device of CH3NH3PbCl3 film ultraviolet photodetectors that were fabricated with a coplanar metal-semiconductor-metal Au interdigital electrode configuration. Pure phase CH3NH3PbCl3 films with a good crystallinity were formed by a hybrid sequential deposition process featured with inter-diffusion of PbCl2 and CH3NH3Cl upon annealing. The CH3NH3PbCl3 film photodetector exhibits a high responsivity of 7.56 A /W at 360 nm, a ultraviolet/visible rejection ratio (R360 nm/R500 nm) was about two orders of magnitude and fast response speed with a rising time of 170 µs and a decay time of 220 µs. All the above results demonstrate CH3NH3PbCl3 film photodetector as a competitive candidate in the application of visible blind UV detectors.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article