Your browser doesn't support javascript.
loading
Effective Dose Rate Coefficients for Immersions in Radioactive Air and Water.
Bellamy, M B; Veinot, K G; Hiller, M M; Dewji, S A; Eckerman, K F; Easterly, C E; Hertel, N E; Leggett, R W.
Afiliação
  • Bellamy MB; Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, P.O. Box 2008 MS 6335, Oak Ridge, TN 37831-6335, USA.
  • Veinot KG; Easterly Scientific, 6412 Westminster Road, Knoxville, TN 37919, USA.
  • Hiller MM; Y-12 National Security Complex, P.O. Box 2009 MS-8206, Oak Ridge, TN 37831-8206, USA.
  • Dewji SA; Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, P.O. Box 2008 MS 6335, Oak Ridge, TN 37831-6335, USA.
  • Eckerman KF; Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, P.O. Box 2008 MS 6335, Oak Ridge, TN 37831-6335, USA.
  • Easterly CE; Easterly Scientific, 6412 Westminster Road, Knoxville, TN 37919, USA.
  • Hertel NE; Easterly Scientific, 6412 Westminster Road, Knoxville, TN 37919, USA.
  • Leggett RW; Oak Ridge National Laboratory, Center for Radiation Protection Knowledge, P.O. Box 2008 MS 6335, Oak Ridge, TN 37831-6335, USA.
Radiat Prot Dosimetry ; 174(2): 275-286, 2017 Apr 25.
Article em En | MEDLINE | ID: mdl-27150517
The Oak Ridge National Laboratory Center for Radiation Protection Knowledge (CRPK) has undertaken a number of calculations in support of a revision to the United States Environmental Protection Agency (US EPA) Federal Guidance Report on external exposure to radionuclides in air, water and soil (FGR 12). Age-specific mathematical phantom calculations were performed for the conditions of submersion in radioactive air and immersion in water. Dose rate coefficients were calculated for discrete photon and electron energies and folded with emissions from 1252 radionuclides using ICRP Publication 107 decay data to determine equivalent and effective dose rate coefficients. The coefficients calculated in this work compare favorably to those reported in FGR12 as well as by other authors that employed voxel phantoms for similar exposure scenarios.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Poluentes Radioativos Limite: Humans País como assunto: America do norte Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Poluentes Radioativos Limite: Humans País como assunto: America do norte Idioma: En Ano de publicação: 2017 Tipo de documento: Article