Your browser doesn't support javascript.
loading
The validity and reliability of a signal impact assessment tool.
Rolfes, Leàn; Kolfschoten, Judith; van Hunsel, Florence; van Puijenbroek, Eugène.
Afiliação
  • Rolfes L; Netherlands Pharmacovigilance Centre Lareb, Hertogenbosch, The Netherlands.
  • Kolfschoten J; Department of Pharmacy: Pharmacotherapy and Pharmaceutical Care, University of Groningen, Groningen, The Netherlands.
  • van Hunsel F; Department of Pharmacy: Pharmacoepidemiology and Clinical Pharmacology, Utrecht University, Utrecht, The Netherlands.
  • van Puijenbroek E; Netherlands Pharmacovigilance Centre Lareb, Hertogenbosch, The Netherlands.
Pharmacoepidemiol Drug Saf ; 25(7): 815-9, 2016 07.
Article em En | MEDLINE | ID: mdl-27193557
ABSTRACT

BACKGROUND:

The Netherlands Pharmacovigilance Centre Lareb uses an operating Signal Impact Assessment Tool (SIAT) as aid in signal selection. SIAT prioritized signals into one of four categories strong/moderate signal strength and similarly health impact. Although the SIAT has been used for many years, validity and reliability was never explored.

PURPOSE:

The aim of this study is to test the validity and reliability of the operating and weight-adjusted SIAT.

METHOD:

For validity testing, judgments of a Delphi panel of three pharmacovigilance experts were used as a 'gold standard'. First, the panel judged the weighting of the items included in the SIAT. Then, during two phases, the panel rated 40 signals in one of the four categories. Two researchers scored the signals using the SIAT. Panel judgments were compared with scores for the operating and weight-adjusted SIAT. Inter- and intra-observer variability was also tested. The Cohen's Kappa coefficient (k) was calculated. At least substantial agreement (k > 0.6) was considered to be necessary for an acceptable reliability.

RESULTS:

Validity did not meet predefined criteria operating and weight-adjusted tool, respectively, k-phase1 = 0.83 and 0.83, k-phase2 = 0.18 and 0.36. Differences were found for signal strength and health impact. Inter- and intra-observer variabilities were good, k of 0.78 and 0.72, respectively.

CONCLUSIONS:

The SIAT was found to have an insufficient validity and proper reliability. Although SIAT scores should not be decisive in the decision making process, items included can be used as an aid to decide which signals deserve further investigation. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sistemas de Notificação de Reações Adversas a Medicamentos / Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos / Farmacovigilância Tipo de estudo: Prognostic_studies Limite: Humans País como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sistemas de Notificação de Reações Adversas a Medicamentos / Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos / Farmacovigilância Tipo de estudo: Prognostic_studies Limite: Humans País como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article