Your browser doesn't support javascript.
loading
The presence of rapid on-site evaluation did not increase the adequacy and diagnostic accuracy of endoscopic ultrasound-guided tissue acquisition of solid pancreatic lesions with core needle.
Fabbri, Carlo; Fuccio, Lorenzo; Fornelli, Adele; Antonini, Filippo; Liotta, Rosa; Frazzoni, Leonardo; Larghi, Alberto; Maimone, Antonella; Paggi, Silvia; Gusella, Paolo; Barresi, Luca; Polifemo, Anna Maria; Iovine, Elio; Macarri, Giampiero; Cennamo, Vincenzo; Tarantino, Ilaria.
Afiliação
  • Fabbri C; Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, 40133, Bologna, Italy. carlo.fabbri@ausl.bologna.it.
  • Fuccio L; Division of Gastroenterology, Department of Medical and Surgical Sciences, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy.
  • Fornelli A; Pathology Service, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy.
  • Antonini F; Department of Gastroenterology, A. Murri Hospital, Fermo, Italy.
  • Liotta R; Pathology Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo, Italy.
  • Frazzoni L; Division of Gastroenterology, Department of Medical and Surgical Sciences, S. Orsola-Malpighi Hospital, University of Bologna, Bologna, Italy.
  • Larghi A; Digestive Endoscopy Unit, Catholic University, Rome, Italy.
  • Maimone A; Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, 40133, Bologna, Italy.
  • Paggi S; Gastroenterology Unit, Valduce Hospital, Como, Italy.
  • Gusella P; Pathology Service, A. Murri Hospital, Polytechnic University of Marche, Fermo, Italy.
  • Barresi L; Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo, Italy.
  • Polifemo AM; Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, 40133, Bologna, Italy.
  • Iovine E; Emergency and General Surgery Department, AUSL Bologna, Bellaria-Maggiore Hospital, Bologna, Italy.
  • Macarri G; Department of Gastroenterology, A. Murri Hospital, Fermo, Italy.
  • Cennamo V; Unit of Gastroenterology and Digestive Endoscopy, AUSL Bologna, Bellaria-Maggiore Hospital, 40133, Bologna, Italy.
  • Tarantino I; Endoscopy Service, Department of Diagnostic and Therapeutic Services, Mediterranean Institute for Transplantation and Advanced Specialized Therapies (ISMETT), Palermo, Italy.
Surg Endosc ; 31(1): 225-230, 2017 01.
Article em En | MEDLINE | ID: mdl-27194261
ABSTRACT

BACKGROUND:

Rapid on-site evaluation (ROSE) improves the adequacy and accuracy of EUS-guided tissue acquisition, although it is not routinely widely available. Evidence suggested that core needles might overcome the absence of ROSE. The aim of this study was to evaluate the influence of ROSE on the adequacy and accuracy of EUS-guided tissue acquisition with core needles in patients with pancreatic solid lesions.

METHODS:

Patients who underwent EUS-guided tissue acquisition of pancreatic mass lesions were retrospectively identified at three tertiary referral centers and those performed with the core needle were included. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without ROSE was the primary outcome measure. The diagnostic accuracy and tissue core acquisition were the secondary outcome measures.

RESULTS:

A total of 333 patients with pancreatic solid mass lesions were included in the study; 140 cases sampled with ROSE and 193 cases without ROSE. The adequacy was 92.1 % in the group sampled with ROSE and 88.1 % in the group without ROSE (p = 0.227). In the ROSE group sensitivity, specificity, and accuracy were 90.7, 100 and 92.1 %, respectively. In the group without ROSE, sensitivity, specificity, and accuracy were 87.2, 100, and 88.1 %, respectively. No difference for all these figures was observed between the two groups. The tissue core was available in 61.4 and 53.4 % of cases with and without ROSE, respectively (p = 0.143).

CONCLUSION:

In the absence of ROSE, EUS-based tissue acquisition with Core needle should be considered since it achieves comparable tissue sampling adequacy and accuracy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Pancreáticas / Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article