Your browser doesn't support javascript.
loading
Gaussian signal relaxation around spin echoes: Implications for precise reversible transverse relaxation quantification of pulmonary tissue at 1.5 and 3 Tesla.
Zapp, Jascha; Domsch, Sebastian; Weingärtner, Sebastian; Schad, Lothar R.
Afiliação
  • Zapp J; Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany.
  • Domsch S; Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany.
  • Weingärtner S; Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany.
  • Schad LR; Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany.
Magn Reson Med ; 77(5): 1938-1945, 2017 05.
Article em En | MEDLINE | ID: mdl-27343149
PURPOSE: To characterize the reversible transverse relaxation in pulmonary tissue and to study the benefit of a quadratic exponential (Gaussian) model over the commonly used linear exponential model for increased quantification precision. METHODS: A point-resolved spectroscopy sequence was used for comprehensive sampling of the relaxation around spin echoes. Measurements were performed in an ex vivo tissue sample and in healthy volunteers at 1.5 Tesla (T) and 3 T. The goodness of fit using χred2 and the precision of the fitted relaxation time by means of its confidence interval were compared between the two relaxation models. RESULTS: The Gaussian model provides enhanced descriptions of pulmonary relaxation with lower χred2 by average factors of 4 ex vivo and 3 in volunteers. The Gaussian model indicates higher sensitivity to tissue structure alteration with increased precision of reversible transverse relaxation time measurements also by average factors of 4 ex vivo and 3 in volunteers. The mean relaxation times of the Gaussian model in volunteers are T2,G' = (1.97 ± 0.27) msec at 1.5 T and T2,G' = (0.83 ± 0.21) msec at 3 T. CONCLUSION: Pulmonary signal relaxation was found to be accurately modeled as Gaussian, providing a potential biomarker T2,G' with high sensitivity. Magn Reson Med 77:1938-1945, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Sinais Assistido por Computador / Imageamento por Ressonância Magnética / Pulmão Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Processamento de Sinais Assistido por Computador / Imageamento por Ressonância Magnética / Pulmão Tipo de estudo: Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article