Your browser doesn't support javascript.
loading
An optimized multiplex flow cytometry protocol for the analysis of intracellular signaling in peripheral blood mononuclear cells.
Davies, Richard; Vogelsang, Petra; Jonsson, Roland; Appel, Silke.
Afiliação
  • Davies R; Broegelmann Research Laboratory, Department of Clinical Science, University of Bergen, Jonas Lies vei 87, 5021 Bergen, Norway. Electronic address: Richard.Davies@uib.no.
  • Vogelsang P; Broegelmann Research Laboratory, Department of Clinical Science, University of Bergen, Jonas Lies vei 87, 5021 Bergen, Norway.
  • Jonsson R; Broegelmann Research Laboratory, Department of Clinical Science, University of Bergen, Jonas Lies vei 87, 5021 Bergen, Norway; Department of Rheumatology, Haukeland University Hospital, 5021 Bergen, Norway.
  • Appel S; Broegelmann Research Laboratory, Department of Clinical Science, University of Bergen, Jonas Lies vei 87, 5021 Bergen, Norway.
J Immunol Methods ; 436: 58-63, 2016 09.
Article em En | MEDLINE | ID: mdl-27369043
ABSTRACT
Phosphoflow cytometry is increasingly being used as a tool for the discovery of biomarkers used in the treatment and monitoring of disease and therapy. The ability to measure numerous phospho-protein targets simultaneously at a single cell level accurately and rapidly provides significant advantages over other methods. We here discuss important considerations required to successfully implement these methods. Three different blood collection tubes (lithium-heparin tubes, CPT with sodium citrate and CPT with sodium heparin) were evaluated, with PBMC isolated through lithium-heparin tubes/lymphoprep displaying reduced basal and increased stimulation induced phosphorylation compared to the other two methods. Further, we provide a protocol outlining an 8 color assay developed for the study of intracellular signaling in peripheral blood mononuclear cells. The assay allows for the quantitative measurement of the phospho-proteins ERK1/2, NF-κB p65, Stat1 (Y701), Stat1 (S727), Stat3 (Y705), Stat3 (S727), Stat4 (Y693), p38 and Stat5 (Y694), as well as the identification of T cells, B cells, natural killer cells and monocytes. The assay additionally incorporates fluorescent cell barcoding, reducing assay costs and increasing throughput while increasing data robustness. Inter-assay precision was assessed over a month long period for all experimental variables (phospho-protein measured, cell type and stimulant). Coefficient of variations (CVs) calculated from process triplicates of normalized median fluorescence intensity (MFI) of the phospho-proteins displayed median CVs under 10% when grouped according to cell type, stimulation agent and phospho-protein measured, while the CV for each triplicate did not exceed 20%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Linfócitos B / Monócitos / Linfócitos T / Transdução de Sinais / Citometria de Fluxo Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Linfócitos B / Monócitos / Linfócitos T / Transdução de Sinais / Citometria de Fluxo Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article