Your browser doesn't support javascript.
loading
Evaluation of the marginal and internal discrepancies of CAD-CAM endocrowns with different cavity depths: An in vitro study.
Shin, Yooseok; Park, Sungho; Park, Jeong-Won; Kim, Kwang-Mahn; Park, Young-Bum; Roh, Byoung-Duck.
Afiliação
  • Shin Y; Clinical Assistant Professor, Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
  • Park S; Professor, Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
  • Park JW; Professor, Department of Conservative Dentistry, College of Dentistry, Gangnam Severance Hospital, Yonsei University, Seoul, Republic of Korea.
  • Kim KM; Professor, Department of Dental Biomaterials, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
  • Park YB; Professor, Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
  • Roh BD; Professor, Department of Conservative Dentistry, Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea. Electronic address: operatys16@yuhs.ac.
J Prosthet Dent ; 117(1): 109-115, 2017 Jan.
Article em En | MEDLINE | ID: mdl-27460311
ABSTRACT
STATEMENT OF

PROBLEM:

The marginal and internal discrepancies of computer-aided design and computer-aided manufacturing (CAD-CAM) endocrowns are unknown.

PURPOSE:

The purpose of this in vitro study was to evaluate the marginal and internal discrepancies of endocrowns with different cavity depths by measuring them with microcomputed tomography (µCT). MATERIAL AND

METHODS:

Endocrowns (n=48) of 2 different cavity depths (2 mm and 4 mm) were fabricated in 2 different chairside CAD-CAM systems (CEREC AC and E4D). A µCT scan was made before and after cementation. For analysis of the marginal and internal discrepancies, reference points were selected in 2-dimensional views of 3 buccolingual cross-sections and 3 mesiodistal cross-sections. To calculate the total discrepancy volume, the µCT sections were reconstructed 3-dimensional views, and changes in volume and surface area were examined. Statistical analysis was performed using 2-way ANOVA with Bonferroni correction (α=.05).

RESULTS:

An endocrown with a 4-mm cavity showed a larger marginal and internal volume than one with a 2-mm cavity. Cementation did not show significant differences in total discrepancy thickness. Discrepancies on the pulpal floor were largest in other sites. Both chairside CAD-CAM systems showed similar discrepancy in the endocrowns.

CONCLUSIONS:

Based on the present study, marginal and internal discrepancies increased depending on cavity depth. Cementation did not increase the dimension of the discrepancy between the restoration and the cavity wall. The discrepancy on the pulpal floor appeared to affect these results.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador / Coroas / Preparo da Cavidade Dentária Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Planejamento de Prótese Dentária / Desenho Assistido por Computador / Coroas / Preparo da Cavidade Dentária Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article