Your browser doesn't support javascript.
loading
Application of lactic acid bacteria in removing heavy metals and aflatoxin B1 from contaminated water.
Elsanhoty, Rafaat M; Al-Turki, I A; Ramadan, Mohamed Fawzy.
Afiliação
  • Elsanhoty RM; Department of Industrial Biotechnology, Institute of Genetic Engineering and Biotechnology, Sadat City University, Sadat City, Egypt.
  • Al-Turki IA; Department of Plant production and Protection, Faculty of Agriculture and Veterinary Medicine, Qassim University, Al-Qassim, Kingdom of Saudi Arabia.
  • Ramadan MF; Agricultural Biochemistry Department, Faculty of Agriculture, Zagazig University, Zagazig 44519, Egypt and Deanship of Scientific Research, Umm Al-Qura University, Makkah, Kingdom of Saudi Arabia E-mail: hassanienmohamed@yahoo.com.
Water Sci Technol ; 74(3): 625-38, 2016.
Article em En | MEDLINE | ID: mdl-27508367
ABSTRACT
In this study selected lactic acid bacteria (LAB, Lactobacillus acidophilus, Lactobacillus rhamnosus, Lactobacillus plantrium and Streptococcus thermophiles) and probiotic bacteria (Bifidobacterium angulatum) were tested for their ability in removing heavy metals (HM) including cadmium (Cd), lead (Pb) and arsenic (As) as well as aflatoxin B1 (AFB1) from contaminated water. The biosorption parameters (pH, bacterial concentration, contact time and temperature) of removal using individual as well as mixed LAB and probiotic bacteria were studied. Removal of HM and AFB1 depended on the strain, wherein the process was strongly pH-dependent with high removal ability at a pH close to neutral. The increase in bacterial concentration enhanced the removal of Cd, Pb and As. Also, increasing of contact time and temperature increased the ability of LAB to remove HM. The effect of contact time on Cd removal was slightly different when freshly cultured cells were used. The removal of Cd, Pb and As decreased with the increase in the initial metal concentration. The most effective HM removers were Lactobacillus acidophilus and Bifidobacterium angulatum. The system was found to be adequate for concentrations of HM under investigation. At the end of the operation, the concentration of HM reached the level allowed by the World Health Organization regulations.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Bifidobacterium / Aflatoxina B1 / Purificação da Água / Metais Pesados / Streptococcus thermophilus / Lactobacillus Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Bifidobacterium / Aflatoxina B1 / Purificação da Água / Metais Pesados / Streptococcus thermophilus / Lactobacillus Tipo de estudo: Evaluation_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article