Your browser doesn't support javascript.
loading
The LG/J murine strain exhibits near-normal tendon biomechanical properties following a full-length central patellar tendon defect.
Arble, Jessica R; Lalley, Andrea L; Dyment, Nathaniel A; Joshi, Pujan; Shin, Dong-Guk; Gooch, Cynthia; Grawe, Brian; Rowe, David; Shearn, Jason T.
Afiliação
  • Arble JR; a Biomedical Engineering Program, College of Engineering and Applied Science , University of Cincinnati , Cincinnati , OH , USA.
  • Lalley AL; b Engineered Skin Laboratories , Shriners Hospital for Children , Cincinnati , OH , USA.
  • Dyment NA; c Department of Reconstructive Sciences, College of Dental Medicine , University of Connecticut Health Center , Farmington , CT , USA.
  • Joshi P; d Computer Science and Engineering , University of Connecticut , Storrs , CT , USA.
  • Shin DG; d Computer Science and Engineering , University of Connecticut , Storrs , CT , USA.
  • Gooch C; a Biomedical Engineering Program, College of Engineering and Applied Science , University of Cincinnati , Cincinnati , OH , USA.
  • Grawe B; e Department of Orthopaedic Surgery, College of Medicine , University of Cincinnati , Cincinnati , OH , USA.
  • Rowe D; c Department of Reconstructive Sciences, College of Dental Medicine , University of Connecticut Health Center , Farmington , CT , USA.
  • Shearn JT; a Biomedical Engineering Program, College of Engineering and Applied Science , University of Cincinnati , Cincinnati , OH , USA.
Connect Tissue Res ; 57(6): 496-506, 2016 11.
Article em En | MEDLINE | ID: mdl-27552106
ABSTRACT
PURPOSE OF THE STUDY Identifying biological success criteria is needed to improve therapies, and one strategy for identifying them is to analyze the RNA transcriptome for successful and unsuccessful models of tendon healing. We have characterized the MRL/MpJ murine strain and found improved mechanical outcomes following a central patellar tendon (PT) injury. In this study, we evaluate the healing of the LG/J murine strain, which comprises 75% of the MRL/MpJ background, to determine if the LG/J also exhibits improved biomechanical properties following injury and to determine differentially expressed transcription factors across the C57BL/6, MRL/MpJ and the LG/J strains during the early stages of healing. MATERIALS AND

METHODS:

A full-length, central PT defect was created in 16-20 week old MRL/MpJ, LG/J, and C57BL/6 murine strains. Mechanical properties were assessed at 2, 5, and 8 weeks post surgery. Transcriptomic expression was assessed at 3, 7, and 14 days following injury using a novel clustering software program to evaluate differential expression of transcription factors.

RESULTS:

Average LG/J structural properties improved to 96.7% and 97.2% of native LG/J PT stiffness and ultimate load by 8 weeks post surgery, respectively. We found the LG/J responded by increasing expression of transcription factors implicated in the inflammatory response and collagen fibril organization.

CONCLUSIONS:

The LG/J strain returns to normal structural properties by 8 weeks, with steadily increasing properties at each time point. Future work will characterize the cell populations responding to injury and investigate the role of the differentially expressed transcription factors during healing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Patela / Tendões Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Patela / Tendões Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article