Your browser doesn't support javascript.
loading
Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.
Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Liang, Kaicheng; Wang, Zhao; Cleveland, Cody; Booth, Lucas; Potsaid, Benjamin; Jayaraman, Vijaysekhar; Cable, Alex E; Mashimo, Hiroshi; Langer, Robert; Traverso, Giovanni; Fujimoto, James G.
Afiliação
  • Lee HC; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Ahsen OO; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Liang K; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Wang Z; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Cleveland C; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA, USA; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge MA, USA; Brigham and Women's Hospital, Boston MA, USA.
  • Booth L; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA, USA; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Potsaid B; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA; Advanced Imaging Group, Thorlabs Inc., Newton NJ, USA.
  • Jayaraman V; Praevium Research Inc., Santa Barbara CA, USA.
  • Cable AE; Advanced Imaging Group, Thorlabs Inc., Newton NJ, USA.
  • Mashimo H; Harvard Medical School, Boston, MA, USA; Veterans Affairs Boston Healthcare System, Boston MA, USA.
  • Langer R; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA, USA; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge MA, USA.
  • Traverso G; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge MA, USA; Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge MA, USA; Brigham and Women's Hospital, Boston MA, USA; Harvard Medical School, Boston, MA, USA.
  • Fujimoto JG; Department of Electrical Engineering & Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge MA, USA.
Biomed Opt Express ; 7(8): 2927-42, 2016 Aug 01.
Article em En | MEDLINE | ID: mdl-27570688
ABSTRACT
We demonstrate a micromotor balloon imaging catheter for ultrahigh speed endoscopic optical coherence tomography (OCT) which provides wide area, circumferential structural and angiographic imaging of the esophagus without contrast agents. Using a 1310 nm MEMS tunable wavelength swept VCSEL light source, the system has a 1.2 MHz A-scan rate and ~8.5 µm axial resolution in tissue. The micromotor balloon catheter enables circumferential imaging of the esophagus at 240 frames per second (fps) with a ~30 µm (FWHM) spot size. Volumetric imaging is achieved by proximal pullback of the micromotor assembly within the balloon at 1.5 mm/sec. Volumetric data consisting of 4200 circumferential images of 5,000 A-scans each over a 2.6 cm length, covering a ~13 cm(2) area is acquired in <18 seconds. A non-rigid image registration algorithm is used to suppress motion artifacts from non-uniform rotational distortion (NURD), cardiac motion or respiration. En face OCT images at various depths can be generated. OCT angiography (OCTA) is computed using intensity decorrelation between sequential pairs of circumferential scans and enables three-dimensional visualization of vasculature. Wide area volumetric OCT and OCTA imaging of the swine esophagus in vivo is demonstrated.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article