Your browser doesn't support javascript.
loading
Polynomial dual energy inverse functions for bone Calcium/Phosphorus ratio determination and experimental evaluation.
Sotiropoulou, P; Fountos, G; Martini, N; Koukou, V; Michail, C; Kandarakis, I; Nikiforidis, G.
Afiliação
  • Sotiropoulou P; Department of Medical Physics, Medical School, University of Patras, Rion, 26500 Patras, Greece.
  • Fountos G; Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo, 12210 Athens, Greece. Electronic address: gfoun@teiath.gr.
  • Martini N; Department of Medical Physics, Medical School, University of Patras, Rion, 26500 Patras, Greece.
  • Koukou V; Department of Medical Physics, Medical School, University of Patras, Rion, 26500 Patras, Greece.
  • Michail C; Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo, 12210 Athens, Greece.
  • Kandarakis I; Radiation Physics, Materials Technology and Biomedical Imaging Laboratory, Department of Biomedical Engineering, Technological Educational Institute of Athens, Egaleo, 12210 Athens, Greece.
  • Nikiforidis G; Department of Medical Physics, Medical School, University of Patras, Rion, 26500 Patras, Greece.
Appl Radiat Isot ; 118: 18-24, 2016 Dec.
Article em En | MEDLINE | ID: mdl-27571965
ABSTRACT
An X-ray dual energy (XRDE) method was examined, using polynomial nonlinear approximation of inverse functions for the determination of the bone Calcium-to-Phosphorus (Ca/P) mass ratio. Inverse fitting functions with the least-squares estimation were used, to determine calcium and phosphate thicknesses. The method was verified by measuring test bone phantoms with a dedicated dual energy system and compared with previously published dual energy data. The accuracy in the determination of the calcium and phosphate thicknesses improved with the polynomial nonlinear inverse function method, introduced in this work, (ranged from 1.4% to 6.2%), compared to the corresponding linear inverse function method (ranged from 1.4% to 19.5%).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Osso e Ossos / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Absorciometria de Fóton / Cálcio Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fósforo / Osso e Ossos / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Absorciometria de Fóton / Cálcio Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article