Your browser doesn't support javascript.
loading
Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes.
Ghoreishi, Seyed Mohammad; Mortazavi, Seyed Ali Akbar; Abtahi, Zahra-Alsadat; Abtahi, Mohammad-Ali; Sonbolestan, Seyed Ali; Abtahi, Seyed-Hossein; Mohammadinia, Mohadeseh; Isfahani, Kimia Nekouie.
Afiliação
  • Ghoreishi SM; Ophthalmology Department, School of Medicine, Feiz Hospital, Isfahan University of Medical Sciences, Qods Sq, Isfahan, Iran.
  • Mortazavi SAA; Isfahan Eye Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Abtahi ZA; Persian Eye Clinic, Isfahan, Iran.
  • Abtahi MA; Ophthalmology Department, School of Medicine, Feiz Hospital, Isfahan University of Medical Sciences, Qods Sq, Isfahan, Iran.
  • Sonbolestan SA; Isfahan Eye Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Abtahi SH; Ophthalmology Department, School of Medicine, Feiz Hospital, Isfahan University of Medical Sciences, Qods Sq, Isfahan, Iran.
  • Mohammadinia M; Isfahan Eye Research Center, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Isfahani KN; Ophthalmology Department, School of Medicine, Feiz Hospital, Isfahan University of Medical Sciences, Qods Sq, Isfahan, Iran. sma.abtahi63@gmail.com.
Int Ophthalmol ; 37(4): 965-971, 2017 Aug.
Article em En | MEDLINE | ID: mdl-27671494
PURPOSE: The purpose of the study was to assess the agreement of anterior segment optical coherence tomography with its older well-known opponent i.e., Sheimpflug imaging in evaluation of the cornea in normal and keratoconus subjects. METHODS: 107 normal and 56 keratoconus eyes were evaluated with the anterior segment optical coherence tomography followed by the Scheimpflug imaging. Parameters included axial keratometry data in both of steep and flat meridians, mean keratometry and the astigmatism values in the central 4.0 mm zone, central, thinnest and apex corneal thicknesses, Q-value in 8 mm zone and pupil diameter. Corneal topographic maps were recorded and were evaluated for anterior highest and lowest points, posterior highest and lowest points. Average values were recorded for analysis. RESULTS: All anterior cornea keratometry indices showed perfect agreement between two devices in normal corneas; while the level of agreement in keratoconus cases ranged from moderate to strong. All posterior keratometry indices also showed perfect agreement in both groups; except for flat K in normal corneas and steep K in KC ones. The amount of corneal cylinder in normal corneas had perfect agreement, and moderate to strong agreement in anterior/posterior cornea in keratoconus group. Anterior highest and lowest points showed strong and perfect agreement in normal and keratoconus cases, respectively. Posterior highest and lowest points showed strong agreement in normal cases. Thickness indices (central, thinnest, and apex thicknesses) showed perfect agreement between two devices in both normal and KC groups. Mean values of anterior and posterior highest points were statistically higher in Scheimpflug system. CONCLUSIONS: Although two imaging technologies had statistically numerical different output, it seems that they have a good agreement in most parameters.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Córnea / Topografia da Córnea / Tomografia de Coerência Óptica / Ceratocone Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Astigmatismo / Córnea / Topografia da Córnea / Tomografia de Coerência Óptica / Ceratocone Tipo de estudo: Etiology_studies / Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article