Your browser doesn't support javascript.
loading
Landfill leachate treatment by sequential membrane bioreactor and electro-oxidation processes.
Zolfaghari, Mehdi; Jardak, Karama; Drogui, Patrick; Brar, Satinder Kaur; Buelna, Gerardo; Dubé, Rino.
Afiliação
  • Zolfaghari M; Institut National de la Recherche Scientifique- Eau, Terre et Environnement (INRS-ETE), Université du Québec, 490 rue de la Couronne, Québec, QC, G1K 9A9, Canada.
  • Jardak K; Institut National de la Recherche Scientifique- Eau, Terre et Environnement (INRS-ETE), Université du Québec, 490 rue de la Couronne, Québec, QC, G1K 9A9, Canada.
  • Drogui P; Institut National de la Recherche Scientifique- Eau, Terre et Environnement (INRS-ETE), Université du Québec, 490 rue de la Couronne, Québec, QC, G1K 9A9, Canada. Electronic address: patrick.drogui@ete.inrs.ca.
  • Brar SK; Institut National de la Recherche Scientifique- Eau, Terre et Environnement (INRS-ETE), Université du Québec, 490 rue de la Couronne, Québec, QC, G1K 9A9, Canada.
  • Buelna G; Centre de Recherche Industrielle du Québec (CRIQ), 333 rue Franquet, Québec, QC, G1P 4C7, Canada.
  • Dubé R; Centre de Recherche Industrielle du Québec (CRIQ), 333 rue Franquet, Québec, QC, G1P 4C7, Canada.
J Environ Manage ; 184(Pt 2): 318-326, 2016 Dec 15.
Article em En | MEDLINE | ID: mdl-27733297
ABSTRACT
Combination of high performance membrane bioreactor (MBR) equipped with ultrafiltration and electro-oxidation process (EOP) by boron-doped diamond electrode (BDD) was used to effectively treat highly contaminated old landfill leachate. MBR and EOP were optimized for raw and pretreated landfill leachate. Seasonal changes dramatically affected the both processes' performance, as the landfill leachate was ¾ more concentrated in winter. For MBR, organic load rate of 1.2 gCOD/L/day and sludge retention time of 80 days was considered as the optimum operating condition in which COD, TOC, NH4+ and phosphorous removal efficiencies reached the average of 63, 35, 98 and 52%, respectively. The best performance of EOP was in current intensity of 3 A with treatment of time of 120 min. Effluent of electro-oxidation was more toxic due to the presence of radicals and organochlorinated compounds. These compounds were removed by stripping or assimilation of sludge if EOP was used as a pretreatment method. Furthermore, the energy consumption of EOP was decreased from 22 to 16 KWh/m3 for biologically treated and raw landfill leachate, respectively.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Eliminação de Resíduos Líquidos / Reatores Biológicos País como assunto: America do norte Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Eliminação de Resíduos Líquidos / Reatores Biológicos País como assunto: America do norte Idioma: En Ano de publicação: 2016 Tipo de documento: Article