Your browser doesn't support javascript.
loading
Thermal comfort, perceived air quality, and cognitive performance when personally controlled air movement is used by tropically acclimatized persons.
Schiavon, S; Yang, B; Donner, Y; Chang, V W-C; Nazaroff, W W.
Afiliação
  • Schiavon S; Center for the Built Environment, University of California, Berkeley, CA, USA.
  • Yang B; Department of Applied Physics and Electronics, Umeå University, Umeå, Sweden.
  • Donner Y; School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, Singapore.
  • Chang VW; Berkeley Education Alliance for Research in Singapore, Singapore, Singapore.
  • Nazaroff WW; Department of Computer Science, Stanford University, Stanford, CA, USA.
Indoor Air ; 27(3): 690-702, 2017 05.
Article em En | MEDLINE | ID: mdl-27754563
ABSTRACT
In a warm and humid climate, increasing the temperature set point offers considerable energy benefits with low first costs. Elevated air movement generated by a personally controlled fan can compensate for the negative effects caused by an increased temperature set point. Fifty-six tropically acclimatized persons in common Singaporean office attire (0.7 clo) were exposed for 90 minutes to each of five conditions 23, 26, and 29°C and in the latter two cases with and without occupant-controlled air movement. Relative humidity was maintained at 60%. We tested thermal comfort, perceived air quality, sick building syndrome symptoms, and cognitive performance. We found that thermal comfort, perceived air quality, and sick building syndrome symptoms are equal or better at 26°C and 29°C than at the common set point of 23°C if a personally controlled fan is available for use. The best cognitive performance (as indicated by task speed) was obtained at 26°C; at 29°C, the availability of an occupant-controlled fan partially mitigated the negative effect of the elevated temperature. The typical Singaporean indoor air temperature set point of 23°C yielded the lowest cognitive performance. An elevated set point in air-conditioned buildings augmented with personally controlled fans might yield benefits for reduced energy use and improved indoor environmental quality in tropical climates.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Temperatura / Sensação Térmica / Cognição Limite: Adult / Female / Humans / Male País como assunto: Asia Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Temperatura / Sensação Térmica / Cognição Limite: Adult / Female / Humans / Male País como assunto: Asia Idioma: En Ano de publicação: 2017 Tipo de documento: Article