Your browser doesn't support javascript.
loading
Central nervous system MRI and cardiac implantable electronic devices.
Cadieu, Romain; Peron, Marilyne; Le Ven, Florent; Kerdraon, Sébastien; Boutet, Claire; Mansourati, Jacques; Ben Salem, Douraied.
Afiliação
  • Cadieu R; Neuroradiology department, University Hospital of Brest, LaTIM, Inserm UMR 1101, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
  • Peron M; Neuroradiology department, University Hospital of Brest, LaTIM, Inserm UMR 1101, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
  • Le Ven F; Cardiology department, University Hospital of Brest, ORPHY, EA 4324, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
  • Kerdraon S; Neuroradiology department, University Hospital of Brest, LaTIM, Inserm UMR 1101, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
  • Boutet C; Radiology department, University Hospital of Saint-Étienne, North hospital, Inserm U1059, avenue Albert-Raimond, 42055 Saint-Étienne cedex 2, France. Electronic address: claire.boutet@chu-st-etienne.fr.
  • Mansourati J; Cardiology department, University Hospital of Brest, ORPHY, EA 4324, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
  • Ben Salem D; Neuroradiology department, University Hospital of Brest, LaTIM, Inserm UMR 1101, boulevard Tanguy-Prigent, 29609 Brest cedex, France.
J Neuroradiol ; 44(1): 1-9, 2017 Feb.
Article em En | MEDLINE | ID: mdl-27814887
ABSTRACT
As the population ages and indications for MRI increase, it is estimated that 50 to 75% of patients with a cardiac implantable electronic device (CIED) - pacemaker (PM) or implanted cardiac defibrillator (ICD) - will need an MRI during their CIED's lifetime. Three categories of materials are defined MRI compatible, MRI non-compatible, and MRI conditional. MRI compatible CIEDs without electrodes have been developed, but do not allow battery changes, so that they are exclusively indicated for patients whose life expectancy is less than that of the battery (6-7years). For MRI conditional CIEDs, all manufacturers publish restrictions. These restrictions can relate to the patient (size, position in the MRI, body temperature), the MRI parameters (magnetic field), or the examination in itself (gradients, specific absorption rate, duration, isocenter). The neuroradiologist can expect to be confronted with the issue of MRI in patients with a CIED. The purpose of this review is to provide them with updated information on MRI and CIEDs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Desfibriladores Implantáveis / Segurança do Paciente Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Imageamento por Ressonância Magnética / Desfibriladores Implantáveis / Segurança do Paciente Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article