Your browser doesn't support javascript.
loading
In-vessel calibration of the imaging diagnostics for the real-time protection of the JET ITER-like wall.
Huber, V; Huber, A; Kinna, D; Balboa, I; Collins, S; Conway, N; Drewelow, P; Maggi, C F; Matthews, G F; Meigs, A G; Mertens, Ph; Price, M; Sergienko, G; Silburn, S; Wynn, A; Zastrow, K-D.
Afiliação
  • Huber V; Forschungszentrum Jülich GmbH, Supercomputing Centre, 52425 Jülich, Germany.
  • Huber A; Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung-Plasmaphysik, Partner of the Trilateral Euregio Cluster (TEC), 52425 Jülich, Germany.
  • Kinna D; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Balboa I; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Collins S; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Conway N; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Drewelow P; MPI für Plasmaphysik, Greifswald, Germany.
  • Maggi CF; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Matthews GF; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Meigs AG; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Mertens P; Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung-Plasmaphysik, Partner of the Trilateral Euregio Cluster (TEC), 52425 Jülich, Germany.
  • Price M; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Sergienko G; Forschungszentrum Jülich GmbH, Institut für Energie- und Klimaforschung-Plasmaphysik, Partner of the Trilateral Euregio Cluster (TEC), 52425 Jülich, Germany.
  • Silburn S; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
  • Wynn A; York Plasma Institute, University of York, Heslington, York YO10 5DD, United Kingdom.
  • Zastrow KD; CCFE, Culham Science Centre, Abingdon OX14 3DB, United Kingdom.
Rev Sci Instrum ; 87(11): 11D430, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27910322
The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.
Buscar no Google
Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article