Your browser doesn't support javascript.
loading
Validation of Inertial Measurement Units for Upper Body Kinematics.
Morrow, Melissa M B; Lowndes, Bethany; Fortune, Emma; Kaufman, Kenton R; Hallbeck, M Susan.
Afiliação
  • Morrow MMB; 1 Mayo Clinic.
  • Lowndes B; 1 Mayo Clinic.
  • Fortune E; 1 Mayo Clinic.
  • Kaufman KR; 1 Mayo Clinic.
  • Hallbeck MS; 1 Mayo Clinic.
J Appl Biomech ; 33(3): 227-232, 2017 Jul.
Article em En | MEDLINE | ID: mdl-27918696
The purpose of this study was to validate a commercially available inertial measurement unit (IMU) system against a standard lab-based motion capture system for the measurement of shoulder elevation, elbow flexion, trunk flexion/extension, and neck flexion/extension kinematics. The validation analyses were applied to 6 surgical faculty members performing a standard, simulated surgical training task that mimics minimally invasive surgery. Three-dimensional joint kinematics were simultaneously recorded by an optical motion capture system and an IMU system with 6 sensors placed on the head, chest, and bilateral upper and lower arms. The sensor-to-segment axes alignment was accomplished manually. The IMU neck and trunk IMU flexion/extension angles were accurate to within 2.9 ± 0.9 degrees and 1.6 ± 1.1°, respectively. The IMU shoulder elevation measure was accurate to within 6.8 ± 2.7° and the elbow flexion measure was accurate to within 8.2 ± 2.8°. In the Bland-Altman analyses, there were no significant systematic errors present; however, there was a significant inversely proportional error across all joints. As the gold standard measurement increased, the IMU underestimated the magnitude of the joint angle. This study reports acceptable accuracy of a commercially available IMU system; however, results should be interpreted as protocol specific.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenômenos Biomecânicos / Amplitude de Movimento Articular / Cotovelo / Tronco / Pescoço Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenômenos Biomecânicos / Amplitude de Movimento Articular / Cotovelo / Tronco / Pescoço Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article