Your browser doesn't support javascript.
loading
Dual-wavelength retinal images denoising algorithm for improving the accuracy of oxygen saturation calculation.
Xian, Yong-Li; Dai, Yun; Gao, Chun-Ming; Du, Rui.
Afiliação
  • Xian YL; Chinese Academy of Sciences, The Key Laboratory of Adaptive Optics, No. 1 Guangdian Avenue Xihang Port Shuangliu, Chengdu 610209, ChinabUniversity of Electronic Science and Technology of China, School of Optoelectronic Information, No. 4 Block 2 N. Jianshe Road, Chengdu 610054, ChinacChinese Academy
  • Dai Y; Chinese Academy of Sciences, The Key Laboratory of Adaptive Optics, No. 1 Guangdian Avenue Xihang Port Shuangliu, Chengdu 610209, ChinacChinese Academy of Sciences, Institute of Optics and Electronics, No. 1 Guangdian Avenue Xihang Port Shuangliu, Chengdu 610209, China.
  • Gao CM; University of Electronic Science and Technology of China, School of Optoelectronic Information, No. 4 Block 2 N. Jianshe Road, Chengdu 610054, China.
  • Du R; Chinese Academy of Sciences, The Key Laboratory of Adaptive Optics, No. 1 Guangdian Avenue Xihang Port Shuangliu, Chengdu 610209, ChinacChinese Academy of Sciences, Institute of Optics and Electronics, No. 1 Guangdian Avenue Xihang Port Shuangliu, Chengdu 610209, China.
J Biomed Opt ; 22(1): 16004, 2017 01 01.
Article em En | MEDLINE | ID: mdl-28056145
Noninvasive measurement of hemoglobin oxygen saturation ( SO 2 ) in retinal vessels is based on spectrophotometry and spectral absorption characteristics of tissue. Retinal images at 570 and 600 nm are simultaneously captured by dual-wavelength retinal oximetry based on fundus camera. SO 2 is finally measured after vessel segmentation, image registration, and calculation of optical density ratio of two images. However, image noise can dramatically affect subsequent image processing and SO 2 calculation accuracy. The aforementioned problem remains to be addressed. The purpose of this study was to improve image quality and SO 2 calculation accuracy by noise analysis and denoising algorithm for dual-wavelength images. First, noise parameters were estimated by mixed Poisson­Gaussian (MPG) noise model. Second, an MPG denoising algorithm which we called variance stabilizing transform (VST) + dual-domain image denoising (DDID) was proposed based on VST and improved dual-domain filter. The results show that VST + DDID is able to effectively remove MPG noise and preserve image edge details. VST + DDID is better than VST + block-matching and three-dimensional filtering, especially in preserving low-contrast details. The following simulation and analysis indicate that MPG noise in the retinal images can lead to erroneously low measurement for SO 2 , and the denoised images can provide more accurate grayscale values for retinal oximetry.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Retina / Vasos Retinianos / Algoritmos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Retina / Vasos Retinianos / Algoritmos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article