Your browser doesn't support javascript.
loading
Evaluation of cancer cell deformability by microcavity array.
Yoshino, Tomoko; Tanaka, Tsuyoshi; Nakamura, Seita; Negishi, Ryo; Shionoiri, Nozomi; Hosokawa, Masahito; Matsunaga, Tadashi.
Afiliação
  • Yoshino T; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan. Electronic address: y-tomoko@cc.tuat.ac.jp.
  • Tanaka T; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Nakamura S; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Negishi R; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Shionoiri N; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Hosokawa M; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
  • Matsunaga T; Division of Biotechnology and Life Science, Institute of Engineering, Tokyo University of Agriculture and Technology, 2-24-16, Naka-cho, Koganei, Tokyo, 184-8588, Japan.
Anal Biochem ; 520: 16-21, 2017 03 01.
Article em En | MEDLINE | ID: mdl-28057503
ABSTRACT
A cell entrapment device consisting of a microcavity array was used to analyze the deformability of MCF-10 human breast epithelial and MCF-7 human breast cancer cell lines by confocal laser scanning microscopy. Entrapment of up to 8 × 103 cells was achieved within 3 min. Protrusions were formed at the bottom surface of the array with a pore size of 3 µm. Protrusion length increased at higher filtration pressures and could be used to distinguish between MCF-7 and MCF-10 cells. These results indicate that our system is useful for high-throughput deformability analysis of cancer cells, which can provide insight into the mechanisms underlying tumor cell malignancy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Forma Celular Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Forma Celular Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article