Your browser doesn't support javascript.
loading
The accuracy of a hand-held navigation system in total knee arthroplasty.
Loh, Bryan; Chen, Jerry Yongqiang; Yew, Andy Khye Soon; Pang, Hee Nee; Tay, Darren Keng Jin; Chia, Shi-Lu; Lo, Ngai Nung; Yeo, Seng Jin.
Afiliação
  • Loh B; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore. zantesuken@hotmail.com.
  • Chen JY; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore. yqjchen@gmail.com.
  • Yew AKS; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
  • Pang HN; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
  • Tay DKJ; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
  • Chia SL; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
  • Lo NN; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
  • Yeo SJ; Department of Orthopaedic Surgery, Singapore General Hosptial, The Academia, 20 College Road, Singapore, 169856, Singapore.
Arch Orthop Trauma Surg ; 137(3): 381-386, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28120025
ABSTRACT

INTRODUCTION:

This study aims to evaluate the effectiveness of a new hand-held navigation system. The authors of this study hypothesize that this navigation system will improve overall lower limb alignment and implant placement without causing a delay in surgery. PATIENTS AND

METHODS:

Two hundred consecutive patients diagnosed with tricompartmental osteoarthritis and underwent total knee arthroplasty by a senior surgeon were included in this study. One hundred patients underwent TKA using the hand-held navigation system, while the other 100 patients underwent TKA using the conventional technique. The primary outcomes of this study were the overall alignment of the lower limb and the position of the components. This was determined radiologically using the (1) Hip-Knee-Ankle angle (HKA) for lower limb alignment; (2) Coronal Femoral-Component angle (CFA); and (3) Coronal Tibia-Component angle (CTA) for component position. Normal alignment was taken as 180° ± 3° for the HKA and 90° ± 3° for both the CFA and CTA.

RESULTS:

For the CFA, the proportion of outliers was 7 and 17% in the hand-held navigation and conventional group, respectively (p = 0.030). For the HKA and CTA, there was no difference in the proportion of outliers between the two groups. The duration of surgery was 73 ± 9 min and 87 ± 15 min in the hand-held navigation and conventional group, respectively (p < 0.001).

CONCLUSION:

This hand-held navigation system is an effective intraoperative tool for reducing the proportion of outliers for femoral implant placement as well as the duration of surgery. The authors conclude that it can be considered for use to check femoral implant placement intra-operatively. LEVEL OF EVIDENCE III.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Cirurgia Assistida por Computador Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article