Diagnostic accuracy of GPs when using an early-intervention decision support system: a high-fidelity simulation.
Kostopoulou, Olga; Porat, Talya; Corrigan, Derek; Mahmoud, Samhar; Delaney, Brendan C.
Afiliação
  • Kostopoulou O; Department of Surgery and Cancer, Imperial College London, London.
  • Porat T; Department of Primary Care and Public Health Sciences, King's College London, London.
  • Corrigan D; Health Research Board Centre for Primary Care Research, Royal College of Surgeons in Ireland, Dublin.
  • Mahmoud S; Department of Primary Care and Public Health Sciences, King's College London, London.
  • Delaney BC; Department of Surgery and Cancer, Imperial College London, London.
Br J Gen Pract ; 67(656): e201-e208, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28137782
ABSTRACT

BACKGROUND:

Observational and experimental studies of the diagnostic task have demonstrated the importance of the first hypotheses that come to mind for accurate diagnosis. A prototype decision support system (DSS) designed to support GPs' first impressions has been integrated with a commercial electronic health record (EHR) system.

AIM:

To evaluate the prototype DSS in a high-fidelity simulation. DESIGN AND

SETTING:

Within-participant

design:

34 GPs consulted with six standardised patients (actors) using their usual EHR. On a different day, GPs used the EHR with the integrated DSS to consult with six other patients, matched for difficulty and counterbalanced.

METHOD:

Entering the reason for encounter triggered the DSS, which provided a patient-specific list of potential diagnoses, and supported coding of symptoms during the consultation. At each consultation, GPs recorded their diagnosis and management. At the end, they completed a usability questionnaire. The actors completed a satisfaction questionnaire after each consultation.

RESULTS:

There was an 8-9% absolute improvement in diagnostic accuracy when the DSS was used. This improvement was significant (odds ratio [OR] 1.41, 95% confidence interval [CI] = 1.13 to 1.77, P<0.01). There was no associated increase of investigations ordered or consultation length. GPs coded significantly more data when using the DSS (mean 12.35 with the DSS versus 1.64 without), and were generally satisfied with its usability. Patient satisfaction ratings were the same for consultations with and without the DSS.

CONCLUSION:

The DSS prototype was successfully employed in simulated consultations of high fidelity, with no measurable influences on patient satisfaction. The substantially increased data coding can operate as motivation for future DSS adoption.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diagnóstico por Computador / Sistemas de Apoio a Decisões Clínicas / Diagnóstico Precoce / Erros de Diagnóstico / Medicina Geral Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diagnóstico por Computador / Sistemas de Apoio a Decisões Clínicas / Diagnóstico Precoce / Erros de Diagnóstico / Medicina Geral Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged País como assunto: Europa Idioma: En Ano de publicação: 2017 Tipo de documento: Article