Your browser doesn't support javascript.
loading
Multivalent foldamer-based affinity assay for selective recognition of Aß oligomers.
Olajos, Gábor; Bartus, Éva; Schuster, Ildikó; Lautner, Gergely; Gyurcsányi, Róbert E; Szögi, Titanilla; Fülöp, Lívia; Martinek, Tamás A.
Afiliação
  • Olajos G; Institute of Pharmaceutical Analysis, University of Szeged, Somogyi u. 4, 6720 Szeged, Hungary.
  • Bartus É; Institute of Pharmaceutical Analysis, University of Szeged, Somogyi u. 4, 6720 Szeged, Hungary.
  • Schuster I; Department of Medical Chemistry, University of Szeged, Dóm tér 8, 6720 Szeged, Hungary.
  • Lautner G; MTA-BME Lendület Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111 Budapest, Hungary.
  • Gyurcsányi RE; MTA-BME Lendület Chemical Nanosensors Research Group, Department of Inorganic and Analytical Chemistry, Budapest University of Technology and Economics, Szt. Gellért tér 4, 1111 Budapest, Hungary.
  • Szögi T; Department of Medical Chemistry, University of Szeged, Dóm tér 8, 6720 Szeged, Hungary.
  • Fülöp L; Department of Medical Chemistry, University of Szeged, Dóm tér 8, 6720 Szeged, Hungary. Electronic address: fulop.livia@med.u-szeged.hu.
  • Martinek TA; Institute of Pharmaceutical Analysis, University of Szeged, Somogyi u. 4, 6720 Szeged, Hungary. Electronic address: martinek@pharm.u-szeged.hu.
Anal Chim Acta ; 960: 131-137, 2017 Apr 01.
Article em En | MEDLINE | ID: mdl-28193356
ABSTRACT
Mimicking the molecular recognition functionality of antibodies is a great challenge. Foldamers are attractive candidates because of their relatively small size and designable interaction surface. This paper describes a sandwich type enzyme-linked immunoassay with a tetravalent ß-peptide foldamer helix array as capture element and enzyme labeled tracer antibodies. The assay was found to be selective to ß-amyloid oligomeric species with surface features transiently present in ongoing aggregation. In optimized conditions, with special emphasis on the foldamer immobilization, a detection limit of 5 pM was achieved with a linear range of 10-500 pM. These results suggest that protein mimetic foldamers can be useful tools in biosensors and affinity assays.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Peptídeos beta-Amiloides / Multimerização Proteica Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática / Peptídeos beta-Amiloides / Multimerização Proteica Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2017 Tipo de documento: Article