Your browser doesn't support javascript.
loading
Deep Brain Stimulation of the Dentato-Rubro-Thalamic Tract: Outcomes of Direct Targeting for Tremor.
Fenoy, Albert J; Schiess, Mya C.
Afiliação
  • Fenoy AJ; Department of Neurosurgery, Mischer Neuroscience Institute, McGovern Medical School, University of Texas - Houston Health Science Center, Houston, TX, USA.
  • Schiess MC; Department of Neurology, Movement Disorders and Neurodegenerative Disease Program, McGovern Medical School, University of Texas - Houston Health Science Center, Houston, TX, USA.
Neuromodulation ; 20(5): 429-436, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28256785
OBJECTIVES: Targeting the dentato-rubro-thalamic tract (DRTt) has been suggested to be efficacious in deep brain stimulation (DBS) for tremor suppression, both in case reports and post-hoc analyses. This prospective observational study sought to analyze outcomes after directly targeting the DRTt in tremor patients. METHODS: 20 consecutively enrolled intention tremor patients obtained pre-operative MRI with diffusion tensor (dTi) sequences. Mean baseline tremor amplitude based on The Essential Tremor Rating Assessment Scale was recorded. The DRTt was drawn for each individual on StealthViz software (Medtronic) using the dentate nucleus as the seed region and the ipsilateral pre-central gyrus as the end region and then directly targeted during surgery. Intraoperative testing confirmed successful tremor control. Post-operative analysis of electrode position relative to the DRTt was performed, as was post-operative assessment of tremor improvement. RESULTS: The mean age of patients was 66.8 years; mean duration of tremor was 16 years. Mean voltage for the L electrode = 3.4 V; R = 2.6 V. Mean distance from the center of the active electrode contact to the DRTt was 0.9 mm on the L, and 0.8 mm on the R. Improvement in arm tremor amplitude from baseline after DBS was significant (P < 0.001). CONCLUSION: Direct targeting of the DRTt in DBS is an effective strategy for tremor suppression. Accounting for hardware, software, and model limitations, depiction of the DRTt allows for placement of electrode contacts directly within the fiber tract for modulation despite any anatomical variation, which reproducibly resulted in good tremor control.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tálamo / Tremor / Núcleo Rubro / Núcleos Cerebelares / Estimulação Encefálica Profunda Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tálamo / Tremor / Núcleo Rubro / Núcleos Cerebelares / Estimulação Encefálica Profunda Tipo de estudo: Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article