Reversal of severe mitral regurgitation by device closure of a large patent ductus arteriosus in a premature infant.
Cardiol Young
; 27(1): 189-192, 2017 Jan.
Article
em En
| MEDLINE
| ID: mdl-28281414
We report a critically ill premature infant with severe mitral valve regurgitation associated with pulmonary hypertension and a severely dilated left atrium from a large patent ductus arteriosus. The mitral valve regurgitation improved significantly with normalisation of left atrial size 4 weeks after percutaneous closure of the patent ductus arteriosus. This case highlights the potential reversibility of severe mitral valve regurgitation with treatment of an underlying cardiac shunt.