Your browser doesn't support javascript.
loading
Transfer learning from RF to B-mode temporal enhanced ultrasound features for prostate cancer detection.
Azizi, Shekoofeh; Mousavi, Parvin; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Xu, Sheng; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Abolmaesumi, Purang.
Afiliação
  • Azizi S; The University of British Columbia, Vancouver, BC, Canada. shazizi@ece.ubc.ca.
  • Mousavi P; Queen's University, Kingston, ON, Canada.
  • Yan P; Philips Research North America, Cambridge, MA, USA.
  • Tahmasebi A; Philips Research North America, Cambridge, MA, USA.
  • Kwak JT; Sejong University, Gwangjin-Gu, SU, Korea.
  • Xu S; National Institutes of Health, Bethesda, MD, USA.
  • Turkbey B; National Institutes of Health, Bethesda, MD, USA.
  • Choyke P; National Institutes of Health, Bethesda, MD, USA.
  • Pinto P; National Institutes of Health, Bethesda, MD, USA.
  • Wood B; National Institutes of Health, Bethesda, MD, USA.
  • Abolmaesumi P; The University of British Columbia, Vancouver, BC, Canada.
Int J Comput Assist Radiol Surg ; 12(7): 1111-1121, 2017 Jul.
Article em En | MEDLINE | ID: mdl-28349507
ABSTRACT

PURPOSE:

We present a method for prostate cancer (PCa) detection using temporal enhanced ultrasound (TeUS) data obtained either from radiofrequency (RF) ultrasound signals or B-mode images.

METHODS:

For the first time, we demonstrate that by applying domain adaptation and transfer learning methods, a tissue classification model trained on TeUS RF data (source domain) can be deployed for classification using TeUS B-mode data alone (target domain), where both data are obtained on the same ultrasound scanner. This is a critical step for clinical translation of tissue classification techniques that primarily rely on accessing RF data, since this imaging modality is not readily available on all commercial scanners in clinics. Proof of concept is provided for in vivo characterization of PCa using TeUS B-mode data, where different nonlinear processing filters in the pipeline of the RF to B-mode conversion result in a distribution shift between the two domains.

RESULTS:

Our in vivo study includes data obtained in MRI-guided targeted procedure for prostate biopsy. We achieve comparable area under the curve using TeUS RF and B-mode data for medium to large cancer tumor sizes in biopsy cores (>4 mm).

CONCLUSION:

Our result suggests that the proposed adaptation technique is successful in reducing the divergence between TeUS RF and B-mode data.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imageamento por Ressonância Magnética / Ultrassonografia Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Imageamento por Ressonância Magnética / Ultrassonografia Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article