Your browser doesn't support javascript.
loading
High-Definition Video System for Peripheral Neurorrhaphy in Rats.
Monteiro de Barros, Rui Sergio; Brito, Marcus Vinicius Henriques; Teixeira, Renan Kleber Costa; Yamaki, Vitor Nagai; Costa, Felipe Lobato da Silva; Sabbá, Marcelo Ferreia; Lemos, Marcos Vinicius Vieira; Parente, Igor Costa; Feijó, Daniel Haber.
Afiliação
  • Monteiro de Barros RS; 1 State University of Pará, Belém, Brazil.
  • Brito MVH; 1 State University of Pará, Belém, Brazil.
  • Teixeira RKC; 1 State University of Pará, Belém, Brazil.
  • Yamaki VN; 1 State University of Pará, Belém, Brazil.
  • Costa FLDS; 1 State University of Pará, Belém, Brazil.
  • Sabbá MF; 1 State University of Pará, Belém, Brazil.
  • Lemos MVV; 1 State University of Pará, Belém, Brazil.
  • Parente IC; 1 State University of Pará, Belém, Brazil.
  • Feijó DH; 1 State University of Pará, Belém, Brazil.
Surg Innov ; 24(4): 369-372, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28438068
ABSTRACT

BACKGROUND:

Although all microsurgeries are based on the use of surgical microscopes, several alternative magnification systems have shown promising results. Improvements in image quality facilitated the use of video systems in microsurgeries with safety and accuracy. The aim of this study was to evaluate the use of a low-cost, video-assisted magnification system in peripheral neurorrhaphy in rats.

METHODS:

Twenty Wistar rats were randomly divided into 2 matched groups according to the magnification system used the microscope group, with neurorrhaphy performed under a microscope with an image magnification of 40×; and the video system group, with the procedures performed under a video system composed of a high-definition Sony camcorder DCR-SR42 set to 52× magnification, macro lenses, 42-inch television, and a digital HDMI cable. We analyzed weight, nerve caliber, total surgery time, neurorrhaphy time, number of stitches, and number of axons in both ends (proximal and distal).

RESULTS:

There were no significant differences between groups in weight, nerve caliber, or number of stitches. Neurorrhaphy under the video system took longer (video 5.60 minutes; microscope 3.20 minutes; P < .05). Number of axons was similar between groups, both in proximal and distal stumps.

CONCLUSION:

It is possible to perform a peripheral neurorrhaphy in rats through video system magnification, but with a longer surgical time.