Your browser doesn't support javascript.
loading
Usefulness of thresholds for smear review of neutropenic samples analyzed with a Sysmex XN-10 analyzer.
Ronez, Emily; Geara, Carole; Coito, Sylvie; Jacqmin, Hugues; Cornet, Edouard; Troussard, Xavier; Chatelain, Bernard; Mullier, François.
Afiliação
  • Ronez E; a Haematology Immunology and Transfusion Laboratory , University Hospital Ambroise Paré, Assistance Publique - Hôpitaux de Paris , Boulogne Billancourt , France.
  • Geara C; b Haematology Laboratory , University hospital CAEN , Caen , France.
  • Coito S; c Laboratory Ketterthill , Belval , Luxemburg.
  • Jacqmin H; d Université catholique de Louvain, CHU UCL Namur, Hematology Laboratory, Namur Thrombosis and Haemostasis Centre (NTHC), Namur Research Institute for Life Sciences (NARILIS) , Namu , Belgium.
  • Cornet E; b Haematology Laboratory , University hospital CAEN , Caen , France.
  • Troussard X; b Haematology Laboratory , University hospital CAEN , Caen , France.
  • Chatelain B; d Université catholique de Louvain, CHU UCL Namur, Hematology Laboratory, Namur Thrombosis and Haemostasis Centre (NTHC), Namur Research Institute for Life Sciences (NARILIS) , Namu , Belgium.
  • Mullier F; d Université catholique de Louvain, CHU UCL Namur, Hematology Laboratory, Namur Thrombosis and Haemostasis Centre (NTHC), Namur Research Institute for Life Sciences (NARILIS) , Namu , Belgium.
Scand J Clin Lab Invest ; 77(6): 406-409, 2017 Oct.
Article em En | MEDLINE | ID: mdl-28609162
ABSTRACT
Neutropenia is one of the main criteria for a blood smear review. The objective of this study was to compare the thresholds proposed by the international consensus group for hematology review (1.0 109/L) and the French speaking Group for Cellular Haematology (1.5 109/L) in terms of the number of useless smears. We collected 112,097 analyzed samples from four laboratories equipped with XN instruments (Sysmex, Kobe, Japan) during early 2016. The only exclusion criterion was a leucocyte count below 0.5 109/L. In the absence of abnormal cells and/or morphology suggesting haematological disease, samples were classified as 'negative for morphology' and the differential from the XN-10 was reported. These smear procedures were considered as uninformative. Some 2202 samples met the criterion for neutropenia (<1.5 109/L) for slide review representing 1.96% of the total. These included 1031 with neutropenia alone and 1171 neutropenia plus other abnormalities. Of the 1031 with neutropenia alone, 886 had a neutrophil count between 1.0 109/L and 1.5 109/L. The smear was uninformative for all of these samples. In conclusion, microscopic examination of a blood smear provided very limited information in cases of neutropenia without other abnormalities.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Hematológicos / Neutropenia Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Testes Hematológicos / Neutropenia Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article