Your browser doesn't support javascript.
loading
Comparison of phantom materials for use in quality assurance of microbeam radiation therapy.
Cameron, Matthew; Cornelius, Iwan; Cutajar, Dean; Davis, Jeremy; Rosenfeld, Anatoly; Lerch, Michael; Guatelli, Susanna.
Afiliação
  • Cameron M; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Cornelius I; Australian Synchrotron, Melbourne, VIC 3168, Australia.
  • Cutajar D; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Davis J; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Rosenfeld A; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Lerch M; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
  • Guatelli S; CMRP, University of Wollongong, Wollongong, NSW 2522, Australia.
J Synchrotron Radiat ; 24(Pt 4): 866-876, 2017 Jul 01.
Article em En | MEDLINE | ID: mdl-28664894
Microbeam radiation therapy (MRT) is a promising radiotherapy modality that uses arrays of spatially fractionated micrometre-sized beams of synchrotron radiation to irradiate tumours. Routine dosimetry quality assurance (QA) prior to treatment is necessary to identify any changes in beam condition from the treatment plan, and is undertaken using solid homogeneous phantoms. Solid phantoms are designed for, and routinely used in, megavoltage X-ray beam radiation therapy. These solid phantoms are not necessarily designed to be water-equivalent at low X-ray energies, and therefore may not be suitable for MRT QA. This work quantitatively determines the most appropriate solid phantom to use in dosimetric MRT QA. Simulated dose profiles of various phantom materials were compared with those calculated in water under the same conditions. The phantoms under consideration were RMI457 Solid Water (Gammex-RMI, Middleton, WI, USA), Plastic Water (CIRS, Norfolk, VA, USA), Plastic Water DT (CIRS, Norfolk, VA, USA), PAGAT (CIRS, Norfolk, VA, USA), RW3 Solid Phantom (PTW Freiburg, Freiburg, Germany), PMMA, Virtual Water (Med-Cal, Verona, WI, USA) and Perspex. RMI457 Solid Water and Virtual Water were found to be the best approximations for water in MRT dosimetry (within ±3% deviation in peak and 6% in valley). RW3 and Plastic Water DT approximate the relative dose distribution in water (within ±3% deviation in the peak and 5% in the valley). PAGAT, PMMA, Perspex and Plastic Water are not recommended to be used as phantoms for MRT QA, due to dosimetric discrepancies greater than 5%.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioterapia / Síncrotrons / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radioterapia / Síncrotrons / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article