Your browser doesn't support javascript.
loading
Development of the Implantable Resonator System for Clinical EPR Oximetry.
Caston, Rose M; Schreiber, Wilson; Hou, Huagang; Williams, Benjamin B; Chen, Eunice Y; Schaner, Philip E; Jarvis, Lesley A; Flood, Ann Barry; Petryakov, Sergey V; Kmiec, Maciej M; Kuppusamy, Periannan; Swartz, Harold M.
Afiliação
  • Caston RM; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA. rose.caston@hsc.utah.edu.
  • Schreiber W; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Hou H; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Williams BB; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Chen EY; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Schaner PE; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Jarvis LA; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Flood AB; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Petryakov SV; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Kmiec MM; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Kuppusamy P; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
  • Swartz HM; EPR Center for the Study of Viable Systems at Dartmouth College, Hanover, USA.
Cell Biochem Biophys ; 75(3-4): 275-283, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28687906
Hypoxic tumors are more resistant to radiotherapy and chemotherapy, which decreases the efficacy of these common forms of treatment. We have been developing implantable paramagnetic particulates to measure oxygen in vivo using electron paramagnetic resonance. Once implanted, oxygen can be measured repeatedly and non-invasively in superficial tissues (<3 cm deep), using an electron paramagnetic resonance spectrometer and an external surface-loop resonator. To significantly extend the clinical applications of electron paramagnetic resonance oximetry, we developed an implantable resonator system to obtain measurements at deeper sites. This system has been used to successfully obtain oxygen measurements in animal studies for several years. We report here on recent developments needed to meet the regulatory requirements to make this technology available for clinical use. radio frequency heating is discussed and magnetic resonance compatibility testing of the device has been carried out by a Good Laboratory Practice-certified laboratory. The geometry of the implantable resonator has been modified to meet our focused goal of verifying safety and efficacy for the proposed use of intracranial measurements and also for future use in tissue sites other than the brain. We have encapsulated the device within a smooth cylindrical-shaped silicone elastomer to prevent tissues from adhering to the device and to limit perturbation of tissue during implantation and removal. We have modified the configuration for simultaneously measuring oxygen at multiple sites by developing a linear array of oxygen sensing probes, which each provide independent measurements. If positive results are obtained in additional studies which evaluate biocompatibility and chemical characterization, we believe the implantable resonator will be at a suitable stage for initial testing in human subjects.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oximetria / Espectroscopia de Ressonância de Spin Eletrônica Limite: Animals / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oxigênio / Oximetria / Espectroscopia de Ressonância de Spin Eletrônica Limite: Animals / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article