Your browser doesn't support javascript.
loading
Good clinical results but moderate osseointegration and defect filling of a cell-free multi-layered nano-composite scaffold for treatment of osteochondral lesions of the knee.
Mathis, Dominic T; Kaelin, Raphael; Rasch, Helmut; Arnold, Markus P; Hirschmann, Michael T.
Afiliação
  • Mathis DT; Department of Orthopaedic Surgery and Traumatology, Kantonsspital Baselland (Bruderholz, Liestal, Laufen), 4101, Bruderholz, Switzerland.
  • Kaelin R; LEONARDO, Hirslanden Klinik Birshof, 4142, Münchenstein, Switzerland.
  • Rasch H; Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, 4101, Bruderholz, Switzerland.
  • Arnold MP; University of Basel, Basel, Switzerland.
  • Hirschmann MT; LEONARDO, Hirslanden Klinik Birshof, 4142, Münchenstein, Switzerland.
Knee Surg Sports Traumatol Arthrosc ; 26(4): 1273-1280, 2018 Apr.
Article em En | MEDLINE | ID: mdl-28712029
PURPOSE: The aim of this retrospective study was to evaluate the clinical and radiological results of a nano-composite multi-layered three-dimensional biomaterial scaffold for treatment of osteochondral lesions (OCL) of the knee. It was a particular radiological interest to analyse the osseointegration, filling of the defects and the bone tracer uptake (BTU), and it was hypothesised that this scaffold, which was created to mimic the entire osteo-cartilaginous unit, is integrated within the bone 12 months postoperatively and comes along with improved patients symptoms and function. METHODS: Fourteen patients (male:female = 11:3, mean age ± SD 33.1 ± 10.7 years) treated for OCL (size 1.0-3.5 cm2) were clinically and radiologically evaluated at 1 year postoperatively. The data were prospectively collected including SPECT/CT, Tegner and Lysholm scores. BTU was anatomically localised and volumetrically quantified in SPECT/CT. Defect filling was analysed in CT. Spearman's rho and Wilcoxon test were used for correlation of BTU in SPECT/CT and clinical scores (p < 0.05). RESULTS: A significant improvement in Lysholm knee score (p < 0.001) and slight deterioration in Tegner score were found (p < 0.01). A complete filling of the defect was shown in 14%, a partial filling in 14% and only minor filling was seen in 72%. A significant correlation (p < 0.001) was found between location of osteochondral lesions and increased BTU. At the lesion sites pre- and postoperative BTU was markedly increased and did not show any decrease at 12-month follow-up. Median Tegner and mean Lysholm scores did not correlate with BTU at any time. CONCLUSIONS: Treatment of OCL in the knee joint with a nano-composite multi-layered three-dimensional biomaterial scaffold resulted in a significant clinical improvement at 1-year follow-up. However, osseointegration was still ongoing at 12-month follow-up. LEVEL OF EVIDENCE: Case series, Level IV.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicatrização / Doenças Ósseas / Doenças das Cartilagens / Osseointegração / Alicerces Teciduais / Articulação do Joelho Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicatrização / Doenças Ósseas / Doenças das Cartilagens / Osseointegração / Alicerces Teciduais / Articulação do Joelho Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article