Your browser doesn't support javascript.
loading
T2* Mapping Provides Information That Is Statistically Comparable to an Arthroscopic Evaluation of Acetabular Cartilage.
Morgan, Patrick; Nissi, Mikko J; Hughes, John; Mortazavi, Shabnam; Ellermann, Jutta.
Afiliação
  • Morgan P; 1 Department of Orthopaedic Surgery, University of Minnesota, Minneapolis, MN, USA.
  • Nissi MJ; 2 Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
  • Hughes J; 3 Department of Biostatistics and Informatics, Colorado School of Public Health, University of Colorado Denver, Aurora, CO, USA.
  • Mortazavi S; 4 Department of Radiology, Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA.
  • Ellermann J; 4 Department of Radiology, Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, USA.
Cartilage ; 9(3): 237-240, 2018 07.
Article em En | MEDLINE | ID: mdl-28715906
ABSTRACT
Objectives The purpose of this study was to validate T2* mapping as an objective, noninvasive method for the prediction of acetabular cartilage damage. Methods This is the second step in the validation of T2*. In a previous study, we established a quantitative predictive model for identifying and grading acetabular cartilage damage. In this study, the model was applied to a second cohort of 27 consecutive hips to validate the model. A clinical 3.0-T imaging protocol with T2* mapping was used. Acetabular regions of interest (ROI) were identified on magnetic resonance and graded using the previously established model. Each ROI was then graded in a blinded fashion by arthroscopy. Accurate surgical location of ROIs was facilitated with a 2-dimensional map projection of the acetabulum. A total of 459 ROIs were studied. Results When T2* mapping and arthroscopic assessment were compared, 82% of ROIs were within 1 Beck group (of a total 6 possible) and 32% of ROIs were classified identically. Disease prediction based on receiver operating characteristic curve analysis demonstrated a sensitivity of 0.713 and a specificity of 0.804. Model stability evaluation required no significant changes to the predictive model produced in the initial study. Conclusions These results validate that T2* mapping provides statistically comparable information regarding acetabular cartilage when compared to arthroscopy. In contrast to arthroscopy, T2* mapping is quantitative, noninvasive, and can be used in follow-up. Unlike research quantitative magnetic resonance protocols, T2* takes little time and does not require a contrast agent. This may facilitate its use in the clinical sphere.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cartilagem Articular / Articulação do Quadril / Acetábulo Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cartilagem Articular / Articulação do Quadril / Acetábulo Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article