Your browser doesn't support javascript.
loading
High-throughput quantitation of Fc-containing recombinant proteins in cell culture supernatant by fluorescence polarization spectroscopy.
Thompson, Ben; Clifford, Jerry; Jenns, Mike; Smith, Andrew; Field, Ray; Nayyar, Kalpana; James, David C.
Afiliação
  • Thompson B; Department of Chemical and Biological Engineering, The University of Sheffield, Sheffield, UK.
  • Clifford J; Valitacell Ltd, Pembroke House, 28-32 Upper Pembroke Street, Dublin 2, Ireland.
  • Jenns M; MedImmune, Granta Park, Cambridge, CB21 6GH, UK.
  • Smith A; MedImmune, Granta Park, Cambridge, CB21 6GH, UK.
  • Field R; MedImmune, Granta Park, Cambridge, CB21 6GH, UK.
  • Nayyar K; Abzena, Babraham Research Campus, Babraham, CB22 3AT, UK.
  • James DC; Department of Chemical and Biological Engineering, The University of Sheffield, Sheffield, UK. Electronic address: d.c.james@sheffield.ac.uk.
Anal Biochem ; 534: 49-55, 2017 10 01.
Article em En | MEDLINE | ID: mdl-28716374
Measurement of recombinant protein product titer critically underpins all biopharmaceutical manufacturing process development, as well as diverse research and discovery activity. Here, we describe a simple rapid (<2 min per 96 samples) 96-well microplate-based assay that enables high-throughput quantitation of recombinant immunoglobulin G and Fc-containing IgG derivatives in mammalian cell culture supernatant over a wide dynamic range of 2.5-80 mg/L, using microplate fluorescence polarization (FP) spectroscopy. The solution-phase FP assay is based on the detection of immunoglobulin Fc domain containing analyte binding to FITC-conjugated recombinant Protein G ligand to measure analyte concentration dependent changes in emitted FP. For ease of use and maximal shelf life, we showed that air-dried assay microplates containing pre-formulated ligand that is re-solubilized on addition of analyte containing solution did not affect assay performance, typically yielding an across plate coefficient of variation of <1%, and a between-plate standard deviation below 1%. Comparative assays of the same samples by FP and other commonly used IgG assay formats operating over a similar dynamic range (Protein A HPLC and bio-interferometry) yielded a coefficient of determination >0.99 in each case.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos Fc das Imunoglobulinas / Técnicas de Cultura de Células / Meios de Cultura / Ensaios de Triagem em Larga Escala Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos Fc das Imunoglobulinas / Técnicas de Cultura de Células / Meios de Cultura / Ensaios de Triagem em Larga Escala Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article