Your browser doesn't support javascript.
loading
Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.
Mandell, Jacob C; Rhodes, Jeffrey A; Shah, Nehal; Gaviola, Glenn C; Gomoll, Andreas H; Smith, Stacy E.
Afiliação
  • Mandell JC; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA. jmandell@partners.org.
  • Rhodes JA; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.
  • Shah N; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.
  • Gaviola GC; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.
  • Gomoll AH; Cartilage Repair Center, Department of Orthopedic Surgery, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.
  • Smith SE; Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, 75 Francis St, Boston, MA, 02115, USA.
Skeletal Radiol ; 46(11): 1487-1498, 2017 Nov.
Article em En | MEDLINE | ID: mdl-28717928
ABSTRACT

OBJECTIVE:

Accurate assessment of knee articular cartilage is clinically important. Although 3.0 Tesla (T) MRI is reported to offer improved diagnostic performance, literature regarding the clinical impact of MRI field strength is lacking. The purpose of this study is to compare the diagnostic performance of clinical MRI reports for assessment of cartilage at 1.5 and 3.0 T in comparison to arthroscopy. MATERIALS AND

METHODS:

This IRB-approved retrospective study consisted of 300 consecutive knees in 297 patients who had routine clinical MRI and arthroscopy. Descriptions of cartilage from MRI reports of 165 knees at 1.5 T and 135 at 3.0 T were compared with arthroscopy. The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade of the arthroscopic grading were calculated for each articular surface at 1.5 and 3.0 T. Agreement between MRI and arthroscopy was calculated with the weighted-kappa statistic. Significance testing was performed utilizing the z-test after bootstrapping to obtain the standard error. RESULTS AND

CONCLUSIONS:

The sensitivity, specificity, percent of articular surfaces graded concordantly, and percent of articular surfaces graded within one grade were 61.4%, 82.7%, 62.2%, and 77.5% at 1.5 T and 61.8%, 80.6%, 59.5%, and 75.6% at 3.0 T, respectively. The weighted kappa statistic was 0.56 at 1.5 T and 0.55 at 3.0 T. There was no statistically significant difference in any of these parameters between 1.5 and 3.0 T. Factors potentially contributing to the lack of diagnostic advantage of 3.0 T MRI are discussed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cartilagem Articular / Doenças das Cartilagens / Articulação do Joelho Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cartilagem Articular / Doenças das Cartilagens / Articulação do Joelho Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article