Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis.
Terslev, L; Diamantopoulos, A P; Døhn, U Møller; Schmidt, W A; Torp-Pedersen, S.
Afiliação
  • Terslev L; Center for Rheumatology and Spinal Diseases, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark. Terslev@dadlnet.dk.
  • Diamantopoulos AP; Department of Rheumatology, Hospital of Southern Norway Trust, Kristiansand, Norway.
  • Døhn UM; Center for Rheumatology and Spinal Diseases, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
  • Schmidt WA; Medical Centre for Rheumatology, Immanuel Krankenhaus, Berlin, Germany.
  • Torp-Pedersen S; Department Radiology, Copenhagen University Hospital. Rigshospitalet, Copenhagen, Denmark.
Arthritis Res Ther ; 19(1): 167, 2017 07 20.
Article em En | MEDLINE | ID: mdl-28728567
ABSTRACT
Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used in arthritic conditions and provide recommendations for optimal adjustments. This is addressed through relevant Doppler physics, focusing, for example, on the Doppler shift equation and how angle correction ensures correctly displayed blood velocity. Recommendations for optimal settings are given, focusing especially on pulse repetition frequency (PRF), gain and Doppler frequency and how they impact on detection of flow. Doppler artefacts are inherent and may be affected by the adjustment of settings. The most important artefacts to be aware of, and to be able to eliminate or minimize, are random noise and blooming, aliasing and motion artefacts. Random noise and blooming artefacts can be eliminated by lowering the Doppler gain. Aliasing and motion artefacts occur when the PRF is set too low, and correct adjustment of the PRF is crucial. Some artefacts, like mirror and reverberation artefacts, cannot be eliminated and should therefore be recognised when they occur. The commonly encountered artefacts, their importance for image interpretation and how to adjust Doppler setting in order to eliminate or minimize them are explained thoroughly with imaging examples in this review.