Your browser doesn't support javascript.
loading
Risk factors for hemoptysis complicating 17-18 gauge CT-guided transthoracic needle core biopsy: multivariate analysis of 249 procedures.
Chassagnon, Guillaume; Gregory, Jules; Al Ahmar, Marc; Magdeleinat, Pierre; Legmann, Paul; Coste, Joel; Revel, Marie Pierre.
Afiliação
  • Chassagnon G; Department of Radiology, Paris Descartes University, Sorbonne Paris Cité Groupe Hospitalier Cochin-Hotel Dieu, Paris, France. marie-pierre.revel@aphp.fr.
Diagn Interv Radiol ; 23(5): 347-353, 2017.
Article em En | MEDLINE | ID: mdl-28762333
ABSTRACT

PURPOSE:

We aimed to identify modifiable and nonmodifiable risk factors for hemoptysis complicating computed tomography (CT)-guided transthoracic needle biopsy.

METHODS:

All procedures performed in our institution from November 2013 to May 2015 were reviewed. Hemoptysis was classified as mild if limited to hemoptoic sputum and abundant otherwise. Presence of intra-alveolar hemorrhage on postbiopsy CT images was also evaluated. Patient- and lesion-related variables were considered nonmodifiable, while procedure-related variables were considered modifiable.

RESULTS:

A total of 249 procedures were evaluated. Hemoptysis and alveolar hemorrhage occurred in 18% and 58% of procedures, respectively, and were abundant or significant in 8% and 17% of procedures, respectively. Concordance between the occurrence of significant alveolar hemorrhage (grade ≥2) and hemoptysis was poor (κ=0.28; 95% CI [0.16-0.40]). In multivariate analysis, female gender (P = 0.008), a longer transpulmonary needle path (P = 0.014), and smaller lesion size (P = 0.044) were independent risk factors for hemoptysis. Transpulmonary needle-path length was the only risk factor for abundant hemoptysis with borderline statistical significance (P = 0.049).

CONCLUSION:

The transpulmonary needle path should be as short as possible to reduce the risk of abundant hemoptysis during CT-guided transthoracic needle biopsy.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Hemoptise / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Radiografia Intervencionista / Hemoptise / Neoplasias Pulmonares Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article