Thrombosis in left ventricular assistance device with centrifugal technology: is early thrombolysis a better solution?
Centofanti, Paolo; Baronetto, Andrea; Attisani, Matteo; Ricci, Davide; Simonato, Erika; La Torre, Michele W; Boffini, Massimo; Rinaldi, Mauro.
Afiliação
  • Centofanti P; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Baronetto A; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Attisani M; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Ricci D; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Simonato E; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • La Torre MW; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Boffini M; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
  • Rinaldi M; Department of Cardiac Surgery, University Hospital of Turin, Turin - Italy.
Int J Artif Organs ; 40(11): 629-635, 2017 Oct 27.
Article em En | MEDLINE | ID: mdl-28777390
BACKGROUND: Continuous flow left ventricular assistance devices (CF-LVADs) have revolutionized the treatment of advanced heart failure. Pump replacement for thrombosis is a high-risk procedure with a high perioperative mortality rate with possible recurrence. We aim to summarize our experience using a conservative approach with medical therapy. METHODS: We retrospectively reviewed records of patients who experienced pump thrombosis after LVAD implantation with HeartWare HVAD at our institution, from November 2010 to March 2016. Device thrombosis (DT) was divided into suspected (SDT) and confirmed (CDT). A conservative approach using thrombolysis and heparin was used in all patients. RESULTS: A total of 32 HeartWare HVAD pumps were implanted. Mean age was 59 ± 10 years and the mean time on mechanical support was 19.29 months (±14.06). Pump thrombosis occurred in 7 patients (0.14 patients/year) after a mean time of 733 (231-1,606) days after LVAD implantation. Three out of 7 cases had thrombosis recurrence (43%). Overall 19 episodes were recorded (0.38 event per patient/year). Eighteen out of 19 thrombolytic treatments were successful (94.7%). No patient required LVAD replacement or transfusion of blood products. There was no significant difference in terms of survival between patients who experienced thrombotic events and patients who did not. No major complications related to thrombolysis were recorded. CONCLUSIONS: Systemic thrombolysis plus heparin was an excellent therapeutic option. Early intervention in clinically stable patients without signs of heart failure but with indirect signs of device thrombosis has led to better outcomes.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombose Coronária / Heparina / Coração Auxiliar / Fibrinolíticos / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Trombose Coronária / Heparina / Coração Auxiliar / Fibrinolíticos / Insuficiência Cardíaca Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article