Your browser doesn't support javascript.
loading
Reliability of unipodal and bipodal counter movement jump landings in a recreational male population.
Schwartz, Cédric; Forthomme, Bénédicte; Paulus, Julien; Kaux, Jean-François; Brüls, Olivier; Denoël, Vincent; Croisier, Jean-Louis.
Afiliação
  • Schwartz C; a Laboratory of Human Motion Analysis (LAMH) , University of Lige , Lige , Belgium.
  • Forthomme B; b Department of Architecture, Geology, Environment and Constructions , University of Liège , Liège , Belgium.
  • Paulus J; a Laboratory of Human Motion Analysis (LAMH) , University of Lige , Lige , Belgium.
  • Kaux JF; c Department of Physical Medicine and Rehabilitation , University of Liège , Liège , Belgium.
  • Brüls O; a Laboratory of Human Motion Analysis (LAMH) , University of Lige , Lige , Belgium.
  • Denoël V; b Department of Architecture, Geology, Environment and Constructions , University of Liège , Liège , Belgium.
  • Croisier JL; c Department of Physical Medicine and Rehabilitation , University of Liège , Liège , Belgium.
Eur J Sport Sci ; 17(9): 1143-1152, 2017 Oct.
Article em En | MEDLINE | ID: mdl-28780886
ABSTRACT
Movement patterns during landing have been suggested to be related to injury risk. The purpose of this study was to determine the inter-session reliability of kinematic variables and ground reaction forces during landing in a population of male recreational athletes after a counter movement jump. Both unipodal and bipodal landings were evaluated. Furthermore, the possibility to improve landing reliability with a verbal instruction was also studied. Twenty-four male volunteers with no history of lower extremity trauma were randomly assigned to two groups (with and without verbal landing instruction). An optoelectronic 3D system and force plates were used to measure the lower limb joint angles and the ground reaction forces during landing. Intraclass correlation values show moderate to excellent inter-session reliability for the bipodal task (ICC average 0.80, range 0.46-0.97) and poor to excellent reliability for the unipodal task (ICC average >0.75, range 0.20-0.95). However, large standard errors of measurement values at the ankle joint at impact (27.6 ± 11.5°) and for the vertical ground reaction forces (394 ± 1091 N) show that some variables may not be usable in practice. The verbal instruction had a negative effect on the reliability of unipodal landing but improved the reliability of bipodal landing. These findings show that the reliability of a landing task is influenced by its motor complexity as well as the instruction given to the subject.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exercício Pliométrico / Perna (Membro) Tipo de estudo: Clinical_trials Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Exercício Pliométrico / Perna (Membro) Tipo de estudo: Clinical_trials Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article