Your browser doesn't support javascript.
loading
Preliminary validation of an optimized algorithm for intraocular lens power calculation in keratoconus.
Camps, Vicente J; Piñero, David P; Caravaca, Esteban; De Fez, Dolores.
Afiliação
  • Camps VJ; Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
  • Piñero DP; Department of Optics, Pharmacology and Anatomy, University of Alicante; Department of Ophthalmology (Oftalmar), Vithas Medimar International Hospital, Alicante, Spain.
  • Caravaca E; Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
  • De Fez D; Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.
Indian J Ophthalmol ; 65(8): 690-699, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28820154
PURPOSE: This study aimed to evaluate the theoretical influence on intraocular lens power (PIOL) calculation of the use of keratometric approach for corneal power (Pc) calculation in keratoconus and to develop and validate an algorithm preliminarily to minimize this influence. METHODS: Pcwas calculated theoretically with the classical keratometric approach, the Gaussian equation, and the keratometric approach using a variable keratometric index (nkadj) dependent on r1c(Pkadj). Differences in PIOLcalculations (ΔPIOL) using keratometric and Gaussian Pcvalues were evaluated. Preliminary clinical validation of a PIOLalgorithm using Pkadjwas performed in 13 keratoconus eyes. RESULTS: PIOLunderestimation was present if Pcwas overestimated, and vice versa. Theoretical PIOLoverestimation up to -5.6 D and -6.2 D using Le Grand and Gullstrand eye models was found for a keratometric index of 1.3375. If nkadjwas used, maximal Δ PIOLwas ±1.1 D, with most of the values ≤±0.6 D. Clinically, PIOLunder- and over-estimations ranged from -1.1 to - 0.4 D. No statistically significant differences were found between PIOLobtained with Pkadjand Gaussian equation (P > 0.05). CONCLUSION: The use of the keratometric Pcfor PIOLcalculations in keratoconus can lead to significant errors that may be minimized using a Pkadjapproach.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Algoritmos / Córnea / Óptica e Fotônica / Ceratocone / Lentes Intraoculares / Modelos Teóricos Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Algoritmos / Córnea / Óptica e Fotônica / Ceratocone / Lentes Intraoculares / Modelos Teóricos Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article