Your browser doesn't support javascript.
loading
Method for Estimating Three-Dimensional Knee Rotations Using Two Inertial Measurement Units: Validation with a Coordinate Measurement Machine.
Vitali, Rachel V; Cain, Stephen M; McGinnis, Ryan S; Zaferiou, Antonia M; Ojeda, Lauro V; Davidson, Steven P; Perkins, Noel C.
Afiliação
  • Vitali RV; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. vitalir@umich.edu.
  • Cain SM; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. smcain@umich.edu.
  • McGinnis RS; Department of Electrical and Biomedical Engineering, University of Vermont, Burlington, VT 05405, USA. rsmcginn@uvm.edu.
  • Zaferiou AM; Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612, USA. antonia_zaferiou@rush.edu.
  • Ojeda LV; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. lojeda@umich.edu.
  • Davidson SP; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. stevepd@umich.edu.
  • Perkins NC; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. ncp@umich.edu.
Sensors (Basel) ; 17(9)2017 Aug 27.
Article em En | MEDLINE | ID: mdl-28846613
ABSTRACT
Three-dimensional rotations across the human knee serve as important markers of knee health and performance in multiple contexts including human mobility, worker safety and health, athletic performance, and warfighter performance. While knee rotations can be estimated using optical motion capture, that method is largely limited to the laboratory and small capture volumes. These limitations may be overcome by deploying wearable inertial measurement units (IMUs). The objective of this study is to present a new IMU-based method for estimating 3D knee rotations and to benchmark the accuracy of the results using an instrumented mechanical linkage. The method employs data from shank- and thigh-mounted IMUs and a vector constraint for the medial-lateral axis of the knee during periods when the knee joint functions predominantly as a hinge. The method is carefully validated using data from high precision optical encoders in a mechanism that replicates 3D knee rotations spanning (1) pure flexion/extension, (2) pure internal/external rotation, (3) pure abduction/adduction, and (4) combinations of all three rotations. Regardless of the movement type, the IMU-derived estimates of 3D knee rotations replicate the truth data with high confidence (RMS error < 4 ° and correlation coefficient r ≥ 0.94 ).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Joelho Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Articulação do Joelho Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article