Your browser doesn't support javascript.
loading
An electrochemiluminescence cloth-based biosensor with smartphone-based imaging for detection of lactate in saliva.
Yao, Yong; Li, Huijie; Wang, Dan; Liu, Cuiling; Zhang, Chunsun.
Afiliação
  • Yao Y; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China. zhangcs@scnu.edu.cn zhangcs_scnu@126.com.
  • Li H; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China. zhangcs@scnu.edu.cn zhangcs_scnu@126.com.
  • Wang D; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China. zhangcs@scnu.edu.cn zhangcs_scnu@126.com.
  • Liu C; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China. zhangcs@scnu.edu.cn zhangcs_scnu@126.com.
  • Zhang C; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China. zhangcs@scnu.edu.cn zhangcs_scnu@126.com.
Analyst ; 142(19): 3715-3724, 2017 Oct 07.
Article em En | MEDLINE | ID: mdl-28871304
ABSTRACT
Cloth fabrics and smartphones have become the two things people are most familiar with. Particularly, smartphones are used as portable personal computers, revolutionizing communication and lifestyle. Here, screen-printing technology is applied to fabricate carbon electrodes and electrochemical chambers on a single hydrophilic cloth, while the cloth-based electrochemiluminescence (ECL) signals are read out by using an inexpensive smartphone. Therefore, the ECL detection is available in both low-cost disposable sensors and a portable format, which may be very suitable to be used as a non-invasive monitoring tool for medical diagnostics. As a proof-of-principle, lactate oxidase is immobilized onto the working electrode for the lactate measurement. Under optimized conditions, the lactate levels can be quantified over the range of 0.05-2.5 mM, with a detection limit of 0.035 mM and the relative standard deviations of 4.7%, 5.2% and 5.0% for 0.05, 0.5 and 2.5 mM lactate (n = 5). In addition, the proposed biosensor has an acceptable stability and selectivity. Finally, the ECL biosensor is successfully applied for the determination of lactate in human saliva. These results show that the presented ECL platform has the potential to be applied to non-invasively detect a variety of analytes of medical interest.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Saliva / Têxteis / Técnicas Biossensoriais / Ácido Láctico / Smartphone / Medições Luminescentes Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Saliva / Têxteis / Técnicas Biossensoriais / Ácido Láctico / Smartphone / Medições Luminescentes Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article