Extraction, separation and characterization of endotoxins in water samples using solid phase extraction and capillary electrophoresis-laser induced fluorescence.
Fung, Fun Man; Su, Min; Feng, Hua-Tao; Li, Sam Fong Yau.
Afiliação
  • Fung FM; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore.
  • Su M; Institute for Application of Learning Science and Educational Technology (ALSET), University Hall, Lee Kong Chian Wing UHL #05-01D, 21 Lower Kent Ridge Road, Singapore, 119077, Singapore.
  • Feng HT; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore.
  • Li SFY; Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore.
Sci Rep ; 7(1): 10774, 2017 09 07.
Article em En | MEDLINE | ID: mdl-28883632
ABSTRACT
This study focuses on one of the key environmental threats, endotoxins, also known as lipopolysaccharides (LPS). A capillary electrophoresis method in combination with laser induced fluorescence (LIF) detection was developed for the analysis of endotoxins from 16 different bacterial strains. LPSs were derivatized with the amino-reactive fluorescent dye, fluorescein isothiocyanate (FITC), separated by capillary zone electrophoresis (CZE) under the optimized conditions with the use of 50 mM sodium tetraborate buffer (pH 9.30), and detected by LIF detector. To improve the sensitivity of CZE-LIF detection for the determination of trace amounts of endotoxins and to remove possible interference materials in environmental samples, a solid phase extraction (SPE) pre-concentration technique was applied successfully. The SPE targeted at polysaccharide moieties of LPSs and showed LPS enrichment effects too. CE migration time could also reveal the O-antigen chain lengths of LPSs. This CE method and SPE pretreatment showed linearity at 99.84%, and repeatabilities at 8.44% and 11.0% for endotoxins from E. Coli O55B5 and E. Coli O26B6. The limit of detection (LOD) could reach around 5 ng/mL at optimized condition. The method was applied successfully to the determination of LPS levels in tap water and wastewater, and demonstrated sensitive, reproducible and reliable results.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article