Discrimination of human and nonhuman blood using Raman spectroscopy with self-reference algorithm.
Bian, Haiyi; Wang, Peng; Wang, Jun; Yin, Huancai; Tian, Yubing; Bai, Pengli; Wu, Xiaodong; Wang, Ning; Tang, Yuguo; Gao, Jing.
Afiliação
  • Bian H; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
  • Wang P; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
  • Wang J; Chinese Academy of Sciences, CAS Key Lab of Biomedical Diagnostics, Suzhou Institute of Biomedical E, China.
  • Yin H; Chinese Academy of Sciences, CAS Key Lab of Biomedical Diagnostics, Suzhou Institute of Biomedical E, China.
  • Tian Y; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
  • Bai P; Chinese Academy of Sciences, CAS Key Lab of Biomedical Diagnostics, Suzhou Institute of Biomedical E, China.
  • Wu X; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
  • Wang N; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
  • Tang Y; Shanghai University, School of Mechatronic Engineering and Automation, Shanghai, China.
  • Gao J; Chinese Academy of Sciences, Jiangsu Key Laboratory of Medical Optics, Suzhou Institute of Biomedica, China.
J Biomed Opt ; 22(9): 1-7, 2017 Sep.
Article em En | MEDLINE | ID: mdl-28936824
ABSTRACT
We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm-1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm-1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C-H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.