Your browser doesn't support javascript.
loading
Peripherally inserted central catheters: dependency of radiation exposure from puncture site and level of training.
Jonczyk, Martin; Gebauer, Bernhard; Schnapauff, Dirk; Rotzinger, Roman; Hamm, Bernd; Collettini, Federico.
Afiliação
  • Jonczyk M; 1 Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany.
  • Gebauer B; 2 Berlin Institute of Health (BIH), Berlin, Germany.
  • Schnapauff D; 1 Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany.
  • Rotzinger R; 1 Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany.
  • Hamm B; 1 Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany.
  • Collettini F; 1 Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany.
Acta Radiol ; 59(6): 688-693, 2018 Jun.
Article em En | MEDLINE | ID: mdl-28949259
ABSTRACT
Background Several interventional procedures show a dependency on fluoroscopy times (FT) and level of training. Furthermore, FT and dose area products (DAP) vary depending on access site and target vessel for chest port implantations, but not for other thoracic interventions such as percutaneous coronary interventions. Purpose To evaluate the influence of the combination of venous access site and level of training on FTs and DAPs during peripherally inserted central catheters (PICC) implantations in a large cohort of patients. Material and Methods In this retrospective study, PICC implantations of 681 consecutive patients (385 women, 296 men; mean age = 55.0 ± 16.7 years) were analyzed. Two groups of junior (< 50 interventions) and senior (≥ 50 implantations) radiologists were investigated in respect to FT and DAP during PICC placement procedures. Statistical analysis included the Mann-Whitney U test and the Kruskal-Wallis test. P values < 0.05 were considered significant. Results Senior radiologists required significantly less FT (senior = 0.43 s, junior = 0.53 s, P = 0.041), but there was no significant difference in DAPs (senior = 56.3 µGy*m2, junior = 60.6 µGy*m2, P = 0.151). PICC implantations through the left side resulted in a significant reduction of the median FT by 60.9% (left = 0.45 s, right = 1.15 s, P = 0.010). Conclusion Due to considerable dose reduction, the left-sided puncture, especially via the basilic and brachial veins, performed by well-trained interventional radiologists seem to be the preferable approach for PICCs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Venoso Central / Cateterismo Periférico / Fluoroscopia / Competência Clínica / Exposição à Radiação Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Venoso Central / Cateterismo Periférico / Fluoroscopia / Competência Clínica / Exposição à Radiação Tipo de estudo: Observational_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article