Your browser doesn't support javascript.
loading
Perioperative Fractures in Cementless Total Hip Arthroplasty Using the Direct Anterior Minimally Invasive Approach: Reduced Risk With Short Stems.
Dietrich, Michael; Kabelitz, Method; Dora, Claudio; Zingg, Patrick O.
Afiliação
  • Dietrich M; Department of Orthopaedics and Traumatology, Clinic for Surgery, Waid City Hospital, Zurich, Switzerland.
  • Kabelitz M; Department of Orthopaedics, University of Zurich, Zurich, Switzerland.
  • Dora C; Department of Orthopaedics, University of Zurich, Zurich, Switzerland.
  • Zingg PO; Department of Orthopaedics, University of Zurich, Zurich, Switzerland.
J Arthroplasty ; 33(2): 548-554, 2018 02.
Article em En | MEDLINE | ID: mdl-28993084
ABSTRACT

BACKGROUND:

The direct minimally invasive anterior approach (DMIAA) and the use of uncemented stems demonstrated an increase in intraoperative fractures in recent literature. Whether the different design of the stems additionally influences the incidence of perioperative local complications, was the goal of this study.

METHODS:

From January 2008 until June 2010, all patients undergoing primary cementless total hip arthroplasty, using a DMIAA, were consecutively included. The choice of the implant was defined by the day of operation. Age, gender, body mass index, type of prosthesis, and the practical experience of the performing surgeon were retrospectively analyzed. Of main interest were intraoperative fractures, postoperative hematoma, and wound healing.

RESULTS:

Six hundred forty consecutive patients (64 years [18-94], 339 female, 53%, body mass index 26) have been included. A Quadra-H stem (Medacta) was used in 457 patients (71%). In 183 (29%) patients, a short stem designed for the DMIAA (130 Fitmore, Zimmer and 53 AMIStem, Medacta) was used. We counted 34 (5.3%) intraoperative fractures (16 at the greater trochanter, 18 proximal shaft fractures), 20 (4%) hematomas, and 8 (2%) wound healing problems. The standard length stem showed more local complications (11.8% vs 4.4%) (P = .014, odds ratio 1.63, confidence interval 1.1-2.4) and significantly more (6.8% vs 1.6%) intraoperative fractures (P = .027, odds ratio 1.98, confidence interval 1.1-3.6).

CONCLUSION:

The standard length stem showed more perioperative complications, especially periprosthetic fractures. It seems that these implants not only put more stress to proximal osseous structures, but there might also be more traction and irritation to the soft tissue while preparing, resulting in more hematomas and wound healing problems.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas Periprotéticas / Fraturas do Fêmur / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Fraturas Periprotéticas / Fraturas do Fêmur / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article