Geometric comparison of the mitral and tricuspid valve annulus: Insights from three dimensional transesophageal echocardiography.
Makaryus, Amgad N; Ismail, Haisam; Makaryus, John N; Fan, Dali.
Afiliação
  • Makaryus AN; Hofstra Northwell School of Medicine, Department of Cardiology, North Shore University Hospital, Manhasset, NY 11030, United States.
  • Ismail H; Hofstra Northwell School of Medicine, Department of Cardiology, North Shore University Hospital, Manhasset, NY 11030, United States.
  • Makaryus JN; Hofstra Northwell School of Medicine, Department of Cardiology, North Shore University Hospital, Manhasset, NY 11030, United States.
  • Fan D; Department of Medicine, Division of Cardiology, University of California, Davis, CA 95616, United States.
World J Cardiol ; 9(9): 757-760, 2017 Sep 26.
Article em En | MEDLINE | ID: mdl-29081909
AIM: To apply real time three-dimensional transesophageal echocardiography (RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus (MVA) and tricuspid valve annulus (TVA) in the same patient. METHODS: Our retrospective cohort study examined the MVA and TVA in 49 patients by RT3D TEE. MVA and TVA shape were examined by TEE. The MVA and TVA volume data set images were acquired in the mid esophageal 4-chamber view. The MVA and TVA were acquired separately, with optimization of each for the highest frame rate and image quality. The 3D shape of the annuli was reconstructed using the Philips® Q lab, MVQ ver. 6.0 MVA model software. The end-systolic frame was used. The parameters measured and compared were annular area, circumference, high-low distances (height), anterolateral-posterolateral (ALPM), and anteroposterior (AP) axes. RESULTS: A total of 49 patients (mean age 61 ± 14 years, 45% males) were studied. The ALPM and the AP axes of the MVA and TVA are not significantly different. The ALPM axis of the MVA was 37.9 ± 6.4 mm and 38.0 ± 5.6 mm for the TVA (P = 0.70). The AP axis of the MVA was 34.8 ± 5.7 mm and 34.9 ± 6.2 mm for the TVA (P = 0.90). The MVA and the TVA had similar circumference and area. The circumference of the MVA was 127.9 ± 16.8 mm and 125.92 ± 16.12 mm for the TVA (P = 0.23). The area of the MVA was 1103.7 ± 307.8 mm2 and 1131.7 ± 302.0 mm2 for the TVA (P = 0.41). The MVA and TVA are similar oval structures, but with significantly different heights. The ALPM/AP ratio for the MVA was 1.08 ± 0.33 and 1.09 ± 0.28 for the TVA (P < 0.001). The height for the MVA and TVA was 9.23 ± 2.11 mm and 4.37 ± 1.48 mm, respectively (P < 0.0001). CONCLUSION: RT3D TEE plays an unprecedented role in the management of valvular heart disease. The specific and exclusive shape of the MVA and TVA was revealed in our study of patients studied. Moreover, the intricate codependence of the MVA and the TVA depends on their distinctive shapes. This realization seen from our study will allow us to better understand the role valvular disease plays in disease states such as hypertrophic cardiomyopathy and pulmonary hypertension.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Observational_studies / Qualitative_research Idioma: En Ano de publicação: 2017 Tipo de documento: Article