Your browser doesn't support javascript.
loading
Segmental variations in facet joint translations during in vivo lumbar extension.
Byrne, Ryan M; Zhou, Yu; Zheng, Liying; Chowdhury, Suman K; Aiyangar, Ameet; Zhang, Xudong.
Afiliação
  • Byrne RM; Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, PA 15203, USA.
  • Zhou Y; Department of Industrial & Systems Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Zheng L; Health Effects Lab Division, National Institute for Occupational Safety and Health, Morgantown, WV 26505, USA.
  • Chowdhury SK; Department of Industrial & Systems Engineering, Texas A&M University, College Station, TX 77843, USA.
  • Aiyangar A; Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, PA 15203, USA; Mechanical Systems Engineering, EMPA (Swiss Federal Laboratories for Materials Science and Technology), 8600 Duebendorf, Switzerland. Electronic address: ameet.aiyangar@empa.ch.
  • Zhang X; Department of Industrial & Systems Engineering, Texas A&M University, College Station, TX 77843, USA; Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843, USA. Electronic address: xudongzhang@tamu.edu.
J Biomech ; 70: 88-95, 2018 03 21.
Article em En | MEDLINE | ID: mdl-29096984
ABSTRACT
The lumbar facet joint (FJ) is often associated with pathogenesis in the spine, but quantification of normal FJ motion remains limited to in vitro studies or static imaging of non-functional poses. The purpose of this study was to quantify lumbar FJ kinematics in healthy individuals during functional activity with dynamic stereo radiography (DSX) imaging. Ten asymptomatic participants lifted three known weights starting from a trunk-flexed (∼75°) position to an upright position while being imaged within the DSX system. High resolution computed tomography (CT) scan-derived 3D models of their lumbar vertebrae (L2-S1) were registered to the biplane 2D radiographs using a markerless model-based tracking technique providing instantaneous 3D vertebral kinematics throughout the lifting tasks. Effects of segment level and weight lifted were assessed using mixed-effect repeated measures ANOVA. Superior-inferior (SI) translation dominated FJ translation, with L5S1 showing significantly less translation magnitudes (Median (Md) = 3.5 mm, p < 0.0001) than L2L3, L3L4, and L4L5 segments (Md = 5.9 mm, 6.3 mm and 6.6 mm respectively). Linear regression-based slopes of continuous facet translations revealed strong linearity for SI translation (r2 > 0.94), reasonably high linearity for sideways sliding (Z-) (r2 > 0.8), but much less linearity for facet gap change (X-) (r2 ∼ 0.5). Caudal segments (L4-S1), particularly L5S1, displayed greater coupling compared to cranial (L2-L4) segments, revealing distinct differences overall in FJ translation trends at L5S1. No significant effect of weight lifted on FJ translations was detected. The study presents a hitherto unavailable and highly precise baseline dataset of facet translations measured during a functional, dynamic lifting task.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Remoção / Articulação Zigapofisária / Vértebras Lombares Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Remoção / Articulação Zigapofisária / Vértebras Lombares Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2018 Tipo de documento: Article