Your browser doesn't support javascript.
loading
DCE-MRI of patient-derived xenograft models of uterine cervix carcinoma: associations with parameters of the tumor microenvironment.
Hauge, Anette; Wegner, Catherine S; Gaustad, Jon-Vidar; Simonsen, Trude G; Andersen, Lise Mari K; Rofstad, Einar K.
Afiliação
  • Hauge A; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway.
  • Wegner CS; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway.
  • Gaustad JV; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway.
  • Simonsen TG; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway.
  • Andersen LMK; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway.
  • Rofstad EK; Group of Radiation Biology and Tumor Physiology, Department of Radiation Biology, Institute for Cancer Research, The Norwegian Radium Hospital, Oslo University Hospital, P. O. Box 4953 Nydalen, 0424, Oslo, Norway. einar.k.rofstad@rr-research.no.
J Transl Med ; 15(1): 225, 2017 11 03.
Article em En | MEDLINE | ID: mdl-29100521
ABSTRACT

BACKGROUND:

Abnormalities in the tumor microenvironment are associated with resistance to treatment, aggressive growth, and poor clinical outcome in patients with advanced cervical cancer. The potential of dynamic contrast-enhanced (DCE) MRI to assess the microvascular density (MVD), interstitial fluid pressure (IFP), and hypoxic fraction of patient-derived cervical cancer xenografts was investigated in the present study.

METHODS:

Four patient-derived xenograft (PDX) models of squamous cell carcinoma of the uterine cervix (BK-12, ED-15, HL-16, and LA-19) were subjected to Gd-DOTA-based DCE-MRI using a 7.05 T preclinical scanner. Parametric images of the volume transfer constant (K trans) and the fractional distribution volume (v e) of the contrast agent were produced by pharmacokinetic analyses utilizing the standard Tofts model. Whole tumor median values of the DCE-MRI parameters were compared with MVD and the fraction of hypoxic tumor tissue, as determined histologically, and IFP, as measured with a Millar catheter.

RESULTS:

Both on the PDX model level and the single tumor level, a significant inverse correlation was found between K trans and hypoxic fraction. The extent of hypoxia was also associated with the fraction of voxels with unphysiological v e values (v e > 1.0). None of the DCE-MRI parameters were related to MVD or IFP.

CONCLUSIONS:

DCE-MRI may provide valuable information on the hypoxic fraction of squamous cell carcinoma of the uterine cervix, and thereby facilitate individualized patient management.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Neoplasias do Colo do Útero / Meios de Contraste / Microambiente Tumoral Tipo de estudo: Risk_factors_studies Limite: Animals / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Neoplasias do Colo do Útero / Meios de Contraste / Microambiente Tumoral Tipo de estudo: Risk_factors_studies Limite: Animals / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article